to 4.2 kHz (+0 kHz/–0.1 kHz). 
  Press and hold the [H/L] key for 2 seconds to save the new setting at the band center. 
  Press the [CLR] key to exit from this alignment item. 
 
TX Deviation Adjustment (DCS) 
  Connect  the  wattmeter  and  dummy  load  to  the  antenna  jack,  then  connect  the  deviation 
meter to the antenna jack through the VHF sampling coupler. 
  Press the [ ] or [ ] key to select the display to "DCS". 
  Press  the  [SQL]  key,  then  press  the  [H/L]  key  to  enable  adjustment  of  the  TX  Deviation 
(DCS). 
  Press the PTT key to enable the transmitter and to output a DCS tone, press the [ ] or [ ] 
key to adjust the deviation to 0.6 kHz (±0.1 kHz). 
  Press and hold the [H/L] key for 2 seconds to save the new setting. 
  Press the [CLR] key to exit from this alignment item. 
 
TX Deviation Adjustment (CTCSS) 
  Connect  the  wattmeter  and  dummy  load  to  the  antenna  jack,  then  connect  the  deviation 
meter to the antenna jack through the VHF sampling coupler. 
  Press the [ ] or [ ] key to select the display to "CTCSS". 
  Press  the  [SQL]  key,  then  press  the  [H/L]  key  to  enable  adjustment  of  the  TX  Deviation 
(CTCSS). 
  Press the PTT key to enable the transmitter and to output a CTCSS tone, press the [ ] or 
[ ] key to adjust the deviation to 0.7 kHz (±0.1 kHz). 
  Press and hold the [H/L] key for 2 seconds to save the new setting. 
  Press the [CLR] key to exit from this alignment item. 
Exit from the Alignment mode 
To exit from the Alignment mode, turn the transceiver off.