Page 2
The combustion and ash pit compartment must be kept closed to prevent backdraft of smoke except during ignition, Only spare parts supplied by JC BORDELET must be used. loading or removal of residues. Regular maintenance of your appliance is necessary by a Some parts of the appliance, especially the external surfaces, competent technician.
Page 3
TECHNICAL INFORMATION FREE-STANDING LEA WALL MOUNTED LEA Rated thermal power 9,8kW Useful thermal power emitted in the room 9,8kW Energy efficiency 81,7% Minimum distance between the glass pane of the appliance and all combustible materials 1200mm Minimum distance between the side of the appliance and any combustible materials 1200mm Minimum distance between the bottom of the appliance and any combustible materials 340mm...
Page 4
Ignition REMINDER: The ignition of the appliance must be carried out using this ignition method (reverse ignition).
Page 5
Refuelling Idling Starting Air inlets Air inlets closed open Optimum operation Air inlets correctly adjusted...
Page 7
TROUBLESHOOTING AND REMEDIES ORDERS POSSIBLE REMEDIES Soiling of the glass - Burn wood with humidity <20% Backflow when opening the door - Increase the combustion air supply * Condensation - Check the air supply settings of the unit Corrosion - Clean the unit - Check the frequency of chimney sweeping (twice a year, including once during the period of use) - Clear the flue outlet of any disturbing element (eg satellite dish, etc.) *...
Page 8
ZI de Lhérat 63310 RANDAN Tél: 0470561600 – Fax : 0470561689 www.bordelet.com...