Absorption to Float stage current.
Maximum
Model
Current
Setting (CH1)
* 100A
60A
WP-BC
12/100-3
40A
20A
Note: * Recommended setting (Factory Default Setting)
For Lithium battery type:
Parameters below are required for setting:
• Charging Voltage (13.9 - 14.8V)
• Maximum Charging Current and Termination Charging Current
(current to define when the charging process will terminate)
Maximum
Model
Current
Setting (CH1)
* 100A
60A
WP-BC
12/100-3
40A
20A
Procedure to Equalize Flooded Battery:
DANGER: Explosion Hazard. The battery generates explosive gasses during equalization.
Follow all the battery safety precautions listed in the manual.
DANGER: Explosion Hazard and Risk of Battery damage. When using the equalization mode,
the user has to be sure the battery connected to the channel is a flooded battery type.
Equalizing a non-flooded battery may overcharge it and cause the battery to explode.
CAUTION: Risk of Battery and Equipment damage. Only a Flooded lead-acid battery can be
equalized. Consult your battery manufacturer or read the battery manual when you
try to equalize your batteries. Disconnect any DC load connected to the battery, as
during equalize mode, the charger will produce 15.5V to the batteries. You must
monitor the battery specific gravity throughout the equalization process to determine
the end of the equalizing cycle.
Before setting the equalization mode on the specific channel, please be sure the battery
connected to the specific channel is a flooded battery type. When the battery equalization process
started, the charger will automatically fully charge the selected channel first and follows with 1
WhisperPower Battery Charger
Absorption to Float
Stage Current
Setting (CH1)
Setting (CH2/3)
* 4A / 8A / 12A
3A / 6A / 12A
2A / 4A / 8A
1A / 2A / 4A
Absorption to Float
Stage Current
Setting (CH1)
Setting (CH2/3)
* 4A / 8A / 12A
3A / 6A / 12A
2A / 4A / 8A
1A / 2A / 4A
12 V 100 A
Maximum
Absorption to Float
Current
Stage Current
Setting (CH2/3)
60A
3A / 6A / 12A
40A
2A / 4A / 8A
20A
1A / 2A / 4A
10A
0.5A/ 1.0A/ 2.0A
Maximum
Termination
Current
Charging Current
60A
3A / 6A / 12A
40A
2A / 4A / 8A
20A
1A / 2A / 4A
10A
0.5A/ 1A/ 2A