Advertisement

2019‐09‐09 
 
GAS
HEATER PRO24 – FOR HEATING OF WATER IN HOT TUBS 
 
Use pressure reducer 30mbar, 2kg/h  
 
 
 
 
 
1
 
 
 
 
 
 
 
 
 
 
When draining and there is a risk of freezing, loosen 
 
the nuts D and pull the hoses out of the connection 
so that all water can run out. 
As an accessory there is this handy protective case for the gas heater that protects it from wind and rain. The front part 
is detachable and is removed during use. There is fireproof material behind the heater and on the sides. Above the 
heater an inclined fireproof part leads exhaust fumes away. We also have the blue print for DIY'ers.
Thank you for choosing a gas heater from SpaDealers. The heater is easy 
to use. When connecting to a hot tub, there's a connection kit (A) with 
pump incl. hoses accessories (included in complete hot tub packages). It is 
connected as shown below. For the heater to start it needs a water flow 
created by a pump. Connect the upper connection to the heater and wait 
until water starts seeping out in the lower black nut (1). That means the 
air has been displaced and the pump can be started. Note * The pump 
must not be run dry as this can cause damage to the rotor shaft. When the 
water starts flowing the ignition mechanism is activated automatically. If 
gas is connected and turned on the torch will ignite and start heating the 
water. The three white knobs should all be adjusted to Max. 
TIP!
 When the gas is running out you can turn the knobs for Gas and 
Power set to Min. to take most advantage of the remaining gas. 
 
A
B
C
PROTECTIVE CASE FOR GAS HEATER (item DTHHG)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRO24 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SpaDealers PRO24

  • Page 1 2019‐09‐09    HEATER PRO24 – FOR HEATING OF WATER IN HOT TUBS  Thank you for choosing a gas heater from SpaDealers. The heater is easy  to use. When connecting to a hot tub, there's a connection kit (A) with  pump incl. hoses accessories (included in complete hot tub packages). It is  connected as shown below. For the heater to start it needs a water flow  created by a pump. Connect the upper connection to the heater and wait  until water starts seeping out in the lower black nut (1). That means the  air has been displaced and the pump can be started. Note * The pump  must not be run dry as this can cause damage to the rotor shaft. When the  water starts flowing the ignition mechanism is activated automatically. If  gas is connected and turned on the torch will ignite and start heating the  water. The three white knobs should all be adjusted to Max.  TIP!  When the gas is running out you can turn the knobs for Gas and  Power set to Min. to take most advantage of the remaining gas.      Use pressure reducer 30mbar, 2kg/h                         D          When draining and there is a risk of freezing, loosen    the nuts D and pull the hoses out of the connection  so that all water can run out. ...
  • Page 2 Use your gas heater properly and you will avoid  unnecessary problems not covered by the  warranty.  Here follows the most common problems that can be effectively avoided with  proper maintenance.      The most common problem that can occur is when contaminated water is used and the filter  before the pump clogs up. This stops the water flow. The stove will then switch itself off. No  temperature is displayed and there is no ignition spark. The problem is corrected by cleaning  the filter. If there is also a strainer filter in the pipe "Water Inlet", it can be removed as the  outer filter by itself is enough.      One problem that may occur and one that is serious in terms of safety, is a gas leakage. Use  the supplied brass connector and seal. There are clear instructions on page 5 of the manual.  Before the gas heater is taken into service, also test it for leaks. When gas leakage occurs, a  fire results, but it can be prevented by following the simple advice given on page 7 of the  manual.   ’ ...
  • Page 3         In standard configuration the gas heater is not protected against rain and such if not placed  under a roof. Water entering the heater leads to electrical failure and the material may start  to rust. It's easy to make a protective shelf that covers the stove.  You must then take into  account the installation regulations with dimensions on page 4 of the manual.  To reduce the minimum safe distance, a refractory material can used. On our website;  www.spadealersuk.com, drawings can also be downloaded. The protective shelf is also  available to order as an accessory.      If the stove is left outside in freezing temperatures then the heat exchanger could freeze and  be destroyed. If the stove is not protected so that water cannot freeze in the heater, it shall be  disconnected and taken indoors where the risk of freezing exists. ...

This manual is also suitable for:

Hgjsd1219

Table of Contents