Operation

4. After the pump has built up pressure in the system
and shut off, check the pressure switch operation by
opening a faucet or two and running enough water
out to bleed off pressure until the pump starts. The
pump should start when pressure drops to 2 Bars
(30 psi) and stop when pressure reaches 3.4 Bars (32
to 50 psi), depending on the setting (Step 4, Page 5).
Run the pump through one or two complete cycles to
verify correct operation. This will also help clean the
system of dirt and scale dislodged during installation.
115VAC
Circuit
Priming Tee
Breaker
Box
Hot - Brown
Neutral - Black
Float Valve
Cistern
Foot Valve
Float Switch:
Up = On
Down = Off
Wiring Connections – Schematic
Hot – Brown
Circuit
Cistern Float
Breaker
Switch
Box
Neutral – Black
Figure 6 – Cistern Booster Application.
Pressure
Switch
Pressure
Tank
City Water Inlet
NOTE: If the pump is connected
directly to the city water line,
install a Flow Switch or
Low Pressure Cutoff if service
may be interrupted.
Hot
Pressure
Pump
Switch
Neutral
5141 1005
Operation As A Rooftop
Reservoir Booster Pump
1. Open both suction and discharge faucets.
2. Turn on power to pump. The pump should start.
3. Let the pump run until all air is out of the system and
the faucet is running only water.
4. When the faucet is running only water, close the
faucet. The pump should run until the water pressure
rises to the pressure switch's OFF setting. The pump
should then stop.
NOTE: Check the system by running it through one
complete pumping cycle to make sure it works. To do
this, open a faucet and bleed off pressure until the
pump starts. Close the faucet, and when the pressure
in the system has built up again, the pump should
stop.
Water to fill Tinaco
Suction
Shut-Off
Pressure
Outlet
Switch
Inlet
Pressure
Tank
Pressure
Relief
Valve
Figure 7 – Tinaco Application.
This completes installation of the pump system.
If you were unsuccessful, please refer to the
Troubleshooting section (Page 7) or call our customer
service technical staff at 1-262-728-5551.
Tinaco
Valve
Bypass
Discharge
Not To Scale
Shut-Off
Valve
6