Leonardo LN2T/1TS-C5-CP Pre-Installation And Installation Manual

Leonardo LN2T/1TS-C5-CP Pre-Installation And Installation Manual

Advertisement

Quick Links

Leonardo
OVEN
Pre-installation and installation manual
LN2T/1TS
LN2T/1TSH
LN3T/1TS
LN3T/1TSH
LN650/1TS

Advertisement

Table of Contents
loading

Summary of Contents for Leonardo LN2T/1TS-C5-CP

  • Page 1 Leonardo OVEN Pre-installation and installation manual LN2T/1TS LN2T/1TSH LN3T/1TS LN3T/1TSH LN650/1TS...
  • Page 2: Table Of Contents

    Leonardo 2T oven technical data ............7 Leonardo 2T hood technical data ............10 Before the installation, read the content of this manual carefully: it contains important information regarding product Leonardo 3T oven technical data ............11...
  • Page 3: Checks Before Purchasing

    (not supplied) eyebolts supplied by the Manufacturer (they are incorrect inside lifting with a single the oven coupling point chamber) Fig.1. Ed. 0121 - 70702551 REV03 Leonardo - Installation...
  • Page 4 Checks before purchasing Survey the installation room to make sure it is ade- • It is possible to maintain the following minimum dis- Fig.2. quate. tances between the oven and the walls, other appli- ances, objects combustible materials Fig.4.: √ Make sure that Fig.3.
  • Page 5 50 mm 50 mm breaker allowing complete disconnection in over- [1.97 in.] [1.97 in.] with suitable systems voltage III category conditions. Fig.4. Ed. 0121 - 70702551 REV03 Leonardo - Installation...
  • Page 6: Oven Technical Data

    Power supply Power Absorption Connection cable Model sumption Model sumption protection (kW) (Nxmm protection (nxA) (kW) (Nxmm (kWh) (kWh) (nxA) LN2T/1TS-C5-CP 3Nx400V 17,0 5x2,5 4x20 LN2T/1TS-C5-CP 3Nx400V 19,2 5x2,5 4x20 13,3 2T H18 LN2T/1TS-B5-CP 3x230V 11,8 29,6 3x40 2T H18 LN2T/1TS-B5-CP...
  • Page 7: Leonardo 2T Oven Technical Data

    Leonardo 2T oven technical data 245mm 9,63in 651,5mm 25,65in 411,5mm 16,21in 457,5mm 18,01in 850,5mm 33,48in 85mm 3,37in 70mm 2,76in 887mm 34,92in 570,50mm 294mm 22,46in 737,50mm 29,04in 127mm 5,00in 11,57in 10mm 0,39in 1308mm 51,50in 1318mm 51,89in refractory metal model surface sheet deck...
  • Page 8 Leonardo 2T oven technical data 1318mm 51,89in 10mm 0,39in 1308mm 51,50in 30mm 1,18in 47mm 1,85in 1148mm 45,20in 58,50mm 2,30in h.18 h.25 400mm [15,77 in.] 470mm [18,52 in.] 174mm [6,86 in.] 244mm [9,61 in.] 279mm [10,98 in.] 349mm [13,74 in.] without steamer 280mm [11,02 in.]...
  • Page 9 Leonardo 2T oven technical data 962mm 37,87in 713mm 28,07in 1308mm 51,50in 1162mm 45,75in inch 17,72 20,87 27,17 30,32 33,47 36,62 1010 39,77 1090 1170 173mm 6,81in Ed. 0121 - 70702551 REV03 Leonardo - Installation...
  • Page 10: Leonardo 2T Hood Technical Data

    Leonardo 2T hood technical data 1084mm 42,68in 731mm 28,78in 583mm 22,95in 1314mm 51,73in 833mm 32,80in 460,50mm 1308mm 51,50in 18,13in 853,50mm 33,60in 475mm 18,70in 80mm 3,15in 147mm 5,79in A Supply input B Oven smoke exhaust C Hood fume inlet D Extraction fan...
  • Page 11: Leonardo 3T Oven Technical Data

    Leonardo 3T oven technical data 449,5mm 17,70in 651mm 25,62in 617,5mm 24,28in 1108,5mm 43,64in 609,5mm 24,00in 70mm 2,76in 1297mm 51,06in 775,50mm 30,53in 942,50mm 37,11in 127mm 5,00in 294mm 11,57in without steamer with steamer 10mm 0,39in 1718mm 67,64in 1728mm 68,03in metal refractory 1230mm 48,58in...
  • Page 12 Leonardo 3T oven technical data 1728mm 68,03in 10mm 30mm 1,18in 0,39in 1718mm 67,64in 47mm 58,50mm 1,83in 1148mm 45,20in 2,30in h.18 h.25 400mm [15,77 in.] 470mm [18,52 in.] 174mm [6,86 in.] 244mm [9,61 in.] without steamer 279mm [10,98 in.] 349mm [13,74 in.] 280mm [11,02 in.]...
  • Page 13 Leonardo 3T oven technical data 1372mm 54,02in 713mm 28,07in 1718mm 67,64in 1572mm 61,89in inch 17,72 20,87 27,17 30,32 33,47 36,62 1010 39,77 1090 173mm 6,81in 1170 Ed. 0121 - 70702551 REV03 Leonardo - Installation...
  • Page 14: Leonardo 3T Hood Technical Data

    Leonardo 3T hood technical data 1084mm 42,68in 1724mm 67,87in 937mm 36,89in 786mm 30,94in 833mm 32,80in 475mm 18,70in 1718mm 67,64in 612,50mm 24,11in 1111,50mm 43,76in 80mm 3,15in 147mm 5,79in A Supply input B Oven smoke exhaust C Hood fume inlet D Extraction fan...
  • Page 15: Leonardo 650 Oven Technical Data

    Leonardo 650 oven technical data 633mm 24,91in 651mm 25,65in 799,5mm 31,48in 561mm 22,09in 795mm 31,30in 728mm 28,66in 1663mm 65,47in 127mm 5,00in 294mm 11,57in 70mm 10mm 2,76in 0,39in 2084mm 82,05in 2094mm 82,44in without with 958,50mm 37,74in 1125,50mm 44,31in steamer steamer PIZZA Ø...
  • Page 16 Leonardo 650 oven technical data 2094mm 82,44in 10mm 0,39in 2084mm 82,05in 30mm 1,18in 58,50mm 2,30in 174mm 47mm 1,85in 1469mm 57,83in 6,86in 1690mm 66,54in without steamer with steamer 799,5mm 31,48in 651,5mm 25,65in 633mm 24,91in A Supply input Equipotential 174mm C Steamer connection...
  • Page 17 Leonardo 650 oven technical data 1738mm 68,43in 1034mm 40,71in 2084mm 82,05in 1936,50mm 76,24in inch 17,72 20,87 27,17 30,32 33,47 36,62 1010 39,77 1090 1170 173mm 6,81in Ed. 0121 - 70702551 REV03 Leonardo - Installation...
  • Page 18: Leonardo 650 Hood Technical Data

    Leonardo 650 hood technical data 1084mm 42,68in 833mm 32,80in 2090mm 82,28in 1045mm 41,14in 1045mm 41,14in 2084mm 82,05in 564mm 475mm 18,70in 731mm 28,78in 795mm 31,30in 22,20in 147mm 5,79in 80mm 3,15in 80mm 3,15in A Supply input B Oven smoke exhaust C Hood fume inlet...
  • Page 19 Ed. 0121 - 70702551 REV03 Leonardo - Installation...
  • Page 20: Installation

    INSTALLATION Symbols used in the manual and on Safety instructions modifications that do not follow the information provided in this manual can cause damages, the labels applied to the machine injuries or fatal accidents and null and void the • Read this guide carefully before installing the warranty.
  • Page 21: Preliminary Operations

    Caution, choking hazard! If left unattended, packaging could be potentially dangerous for both children and animals. Caution, danger of getting in the way! If left unattend- ed, packaging could hinder vehicles and installers dur- ing assembly operations. Ed. 0121 - 70702551 REV03 Leonardo - Installation...
  • Page 22: Transport And Positioning

    Installation Transport and positioning of the oven on the planned base Fig.6. Equipped with personal protection devices, transport the equipment to the place of installation. Use a suitable vehicle capable of bearing the weight of the same: during the transport of the equip- ment, people not involved in the installation are not allowed to pass or stand near the work area.
  • Page 23 247 kg - 544 lb 226 kg - 498 lb LN3T/1TSH - h. 25 262 kg - 577 lb 241 kg - 531 lb If the Leonardo oven must rest LN650/1TS 387 kg - 853 lb 347 kg - 765 lb oven...
  • Page 24: Placing Several Ovens One On Top Of The Other

    Installation Placing several ovens one on top of the other Fig.9. If it is necessary to place several ovens one on top of the other, follow the instructions in the figure. The other ovens must be lifted with the same precautions and methods adopted for the first one.
  • Page 25 Installation BACK/x3 SX/x1 DX/x1 Ed. 0121 - 70702551 REV03 Leonardo - Installation...
  • Page 26: Placing Several Ovens One On Top Of The Other With A Hood Installed

    Installation Placing several ovens one on top of the other with a hood installed Fig.10. If it is necessary to place more ovens on an appliance already fitted with a hood, follow the in- structions in the figure. The other ovens must be lifted with the same precautions and methods adopted for the first one.
  • Page 27 Installation BACK/x3 SX/x1 DX/x1 Ed. 0121 - 70702551 REV03 Leonardo - Installation...
  • Page 28 Installation...
  • Page 29: Serial Number Plate Reading

    (the extractor and switch are not supplied by the Manufacturer). In this type of installation the fumes resulting from the opening of the door will not be extracted. Fig.12. Ed. 0121 - 70702551 REV03 Leonardo - Installation...
  • Page 30: Electrical Connection

    Installation Electrical connection 2/3T Fig.13. exclu- The electrical connection must be carried out sively by qualified personnel after reading the safety warnings at the beginning of the manual. Before installing the appliance, check that systems comply with the regulations in force in the country AC 3 N400 where it is going to be used and...
  • Page 31 11,1 3T H25 LN3T/1TSH-B5-CP 3x230V 27,9 3x32 LN3T/1TSH-B6-US 3x208V 10,8 10,8 30,1 4xAWG8 3x32 LN650/1TS-C5-CP 3Nx400V 28,1 4x32 19,5 11,7 LN650/1TS-B5-CP 3x230V 48,9 4x10 3x50 LN650/1TS-B6-US 3x208V 19,2 11,5 53,4 4xAWG6 3x63 Ed. 0121 - 70702551 REV03 Leonardo - Installation...
  • Page 32 Installation Fig.14. For a correct electrical connection, the appliance must: • be included in an equipotential system in compliance with the current legislation. This connection must be made between different appliances with the terminal marked with the equipotential symbol . The conductor must have a minimum cross-section of 10 mm2 (in compliance with the IEC EN 60335-2-42:2003-09 standard) and be green/yellow;...
  • Page 33 Lower heating element solid state relay Terminal board Thermocouple Light transformer 50VA, 230/12Vac double outlet Θ Steamer Abbreviation STEAMER description Water inlet solenoid valve Heating element Manually reset safety thermostat Heating element switching relay Ed. 0121 - 70702551 REV03 Leonardo - Installation...
  • Page 34 Installation AC3 N 400 Abbreviation PIN description Phase downstream from KM1 Technical room fan From safety thermostat to KM1 coil Phase upstream from KM1 Smoke vent opening motor Cooking chamber lights Steam evacuation Steamer heating element supply Phase downstream from KM1 Abbreviation Description Control panel supply 25.2W, 230Vac/12Vcc...
  • Page 35 Installation 2T-3T AC3 208 Abbreviation PIN description Phase downstream from KM1 Technical room fan From safety thermostat to KM1 coil Phase upstream from KM1 Smoke vent opening motor Cooking chamber lights Steam evacuation Steamer heating element supply Phase downstream from KM1 Abbreviation Description Control panel supply 25.2W, 230Vac/12Vcc...
  • Page 36 Installation AC3 208 Abbreviation PIN description Phase downstream from KM1 Technical room fan From safety thermostat to KM1 coil Phase upstream from KM1 Smoke vent opening motor Cooking chamber lights Steam evacuation Steamer heating element supply Phase downstream from KM1 Abbreviation Description Control panel supply 25.2W, 230Vac/12Vcc...
  • Page 37 Lower heating element solid state relay Terminal board Thermocouple Light transformer 50VA, 230/12Vac Θ double outlet Steamer Abbreviation STEAMER description Water inlet solenoid valve Heating element Manually reset safety thermostat Heating element switching relay Ed. 0121 - 70702551 REV03 Leonardo - Installation...
  • Page 38 Installation AC3 230 Abbreviation PIN description Phase downstream from KM1 Technical room fan From safety thermostat to KM1 coil Phase upstream from KM1 Smoke vent opening motor Cooking chamber lights Steam evacuation Steamer heating element supply Phase downstream from KM1 Abbreviation Description Control panel supply 25.2W, 230Vac/12Vcc...
  • Page 39 The specifications of the CSV file are as follows: • .csv file extension • Name of the file "PrgImp.csv” • Nine columns separated by commas and n+1 lines representing header (specified format) and parameters (see files provided with this specification). Ed. 0121 - 70702551 REV03 Leonardo - Installation...
  • Page 40: Pre-Testing And Final Inspection

    Installation Pre-testing and final inspection √ Positioning checks Reference chapter on page... The oven is checked and tested in the Manufacturer’s plant be- Are installation rooms adequate compliant with the regulations? (correct air ex- fore being delivered to the customer. change, minimum/maximum temperature, etc ...) The “production process check sheet”...
  • Page 41: Steamer Assembly (Option)

    Steamer assembly (option) Steamer accessory mod. N602870184 can be connected to Leonardo series ovens CAUTION! DISCONNECT THE OVEN FROM THE POWER SUPPLY BEFORE INSTALLING THE STEAMER...
  • Page 42 Steamer assembly (option) 1/4”...
  • Page 43 The company cannot be held liable for any print or transcription errors, reserving the right to make changes where deemed suitable without prior notice. Partial reproduction prohibited without the consent of the Manufacturer. The measurements provided are indicative and not binding. The original language used to prepare this manual is Italian: the Manufacturer is not responsible for any translation/interpretation or print errors.

Table of Contents