Stand Alone Power Supply 
PSQ‐2909 / PSQ‐3909 / PSQ‐4909 
PSQ‐2920 / PSQ‐3920 / PSQ‐4920 
USER MANUAL 

Advertisement

Table of Contents
loading

Summary of Contents for Fiberplex PSQ-2909

  • Page 1       USER MANUAL  Stand Alone Power Supply  PSQ‐2909 / PSQ‐3909 / PSQ‐4909  PSQ‐2920 / PSQ‐3920 / PSQ‐4920 ...
  • Page 2       [This page intentionally left blank]...
  • Page 3: General Installation Instructions

    Installation Site  Install the unit in a place where the following conditions are met:   The temperature and the relative humidity of the operating environment must be within the specified limits during operation of the  unit. Values specified are applicable to the air inlets of the unit.   Condensation may not be present during operation. If the unit is installed in a location subject to large variations of ambient  temperature (e.g. in an OB‐van), appropriate precautions must be taken.   Unobstructed airflow is essential for proper operation. Ventilation openings of the unit are a functional part of the design and must  not be obstructed in any way during operation (e.g. ‐ by objects placed upon them, placement of the unit on a soft surface, or  improper installation of the unit within a rack or piece of furniture).   The unit must not be unduly exposed to external heat sources (direct sunlight, spot lights).      Ambient Temperature Units and systems by FiberPlex are generally designed for an ambient temperature range (i.e. temperature of the incoming air) of +5...+40 °C.  When rack mounting the units, the following facts must be considered:   The permissible ambient temperature range for operation of the semiconductor components is 0 °C to +70 °C (commercial  temperature range for operation).   The airflow through the installation must allow exhaust air to remain cooler than 70 °C at all times.   Average temperature increase of the cooling air shall be about 20 C°, allowing for an additional maximum 10 C° increase at the  hottest components.  If the cooling function of the installation must be monitored (e.g. for fan failure or illumination with spot lamps), the exhaust air temperature must  be measured directly above the modules at several places within the enclosure.    Grounding and Power Supply Grounding of units with mains supply (class I equipment) is performed via the protective earth (PE) conductor integrated in a NEMA 5‐15P  connector. Units with battery operation (< 60 V, class III equipment) must be earthed using the 3 pin Phoenix connector. Grounding the unit is one  of the measures for protection against electrical shock hazard (dangerous body currents). Hazardous voltage may not only be caused by defective  power supply insulation, but may also be introduced by the connected audio or control cables.  This equipment may require the use of a different line cord, attachment plug, or both, depending on the available power source at installation. If  the attachment plug needs to be changed, refer servicing to qualified personnel. ...
  • Page 4: Getting Started

    Warranty, Service and Terms and Conditions of Sale  For information about Warranty or Service information, please see our published ‘Terms and Conditions of  Sale’. This document is available on fiberplex.com  or can be obtained by requesting it from  clients@fiberplex.com or calling 301.604.0100.  Disposal  Disposal of Packing Materials   The packing materials have been selected with environmental and disposal issues in mind. All packing material  can be recycled. Recycling packing saves raw materials and reduces the volume of waste. If you need to  dispose of the transport packing materials, recycling is encouraged.  Disposal of Used Equipment   Used equipment contains valuable raw materials as well as substances that must be disposed of  professionally. Please dispose of used equipment via an authorized specialist dealer or via the public waste  disposal system, ensuring any material that can be recycled has been. Please take care that your used  equipment cannot be abused. After having disconnected your used equipment from the mains supply, make  sure that the mains connector and the mains cable are made useless.  Disclaimer  The information in this document has been carefully checked and is believed to be accurate at the time of  publication. However, no liability is assumed by FiberPlex for inaccuracies, errors, or omissions, nor for loss or     damage resulting either directly or indirectly from use of the information contained herein. Introduction  The PSQ‐2909, PSQ‐3909 and PSQ‐4909 are compact AC power supplies that attach to and provide operating  voltage for FiberPlex’s FOI series isolators.  The PSQ‐2920, PSQ‐3920 and PSQ‐4920 are compact low voltage power supplies that attach to and provide  operating voltage for FiberPlex’s FOI series isolators. They can power the FiberPlex FOI units with a 12‐48 VDC  (or 10‐32 VAC) external supply. These Low Voltage power supplies are not polarity sensitive; V+ and V‐ may be  reversed for DC inputs. They are equipped with a resettable fuse to protect both the supply and the FOI.  Getting Started  Initial Inspection  Immediately upon receipt, inspect the shipping container for damage. The container should be retained until  the shipment has been checked for completeness and the equipment has been checked mechanically and  electrically. If the shipment is incomplete, if there is mechanical damage, or if the unit fails to operate notify  FiberPlex and make the shipping materials available for the carrier's inspection.     ...
  • Page 5: Installation Instructions

    Start the captive screws into the FOI face. Do not tighten completely until both are threaded.  Tighten snugly the captive screws, evenly, drawing the faces together. The mounting face of the  FOI should be in uniform contact with the face of the PSQ.              Figure 1 PSQ Installation   Note: The PSQ‐4909 is shown. The PSQ‐2920, PSQ‐3920 and PSQ‐4920 Low Voltage power supplies do  not have the AC adapter cable.     Compatibility  The PSQ series power supplies are compatible with all FOI and FIS style Fiber Optic Isolators. The table below  shows compatibility. See the specifications section in the user manual of your FOI to determine the Size of the  FOI.      FiberPlex FOI Series*  Size  AC Power Supply Low Voltage Power Supply  FOI‐2xxx  Size 2  PSQ‐2909  PSQ‐2920  FOI‐3xxx, TDU‐4000  Size 3  PSQ‐3909  PSQ‐3920  FOI‐4xxx thru FOI‐9xxx  Size 4  PSQ‐4909  PSQ‐4920   Includes both FOI and FIS variants       ...
  • Page 6: Other Considerations

    Other Considerations  TEMPEST Support  TEMPEST is a US Government specification and NATO certification intended to protect valuable and mission  critical information from being intercepted through leaking emanations, including unintentional radio or  electrical signals, sounds, and vibrations. The protection efforts are also known as emission security (EMSEC),  which is a subset of communications security (COMSEC).  Several FiberPlex Technologies FOI units have a variant designated with a ‘T‐ST’ suffix, which has been  rigorously designed and tested to comply with TEMPEST requirements. These units can easily be visually  identified by their silver finish.   An RFI suppressed version of the PSQ‐4909 AC power supplies have been tested with the TEMPEST FOI units  and should be used with those units as part of a complete, certified TEMPEST solution. This version can be  ordered using an ‘R’ suffix after the model number (PSQ‐4909‐R).  When using TEMPEST rated FOI, much care must be taken in both the mating equipment and especially the  copper cabling used in such connection. In addition, the power supplies and/or chassis being uses must have  an ‘R’ suffix. For standalone applications, use a PSQ‐4909‐R (or the older PSQ‐4910‐R) power supply or for a  chassis mounted solution use either an RMC‐3101‐R or RMC‐2101‐R chassis. All the items in the system must  be TEMPEST compliant for the system to properly protect the information.   Specifications    ELECTRICAL SPECIFICATIONS     Min  Typ  Max  Unit  Power Requirement  Input Voltage  100  ‐  240  VAC  PSQ‐x909 AC Supplies  Input Frequency  50  ‐  60  Hz  Output Voltage ...
  • Page 7           Figure 2 PSQ‐4909 Dimensions            Figure 3 PSQ‐4920 Dimensions     ...
  • Page 8   18040-412 Guilford Rd. • Annapolis Junction, MD 20701 fiberplex.com • clients@fiberplex.com • 301.604.0100 UMPX909  150724 ...