e-MOTION WALL-LIGHT WITH 110° MOTION SENSOR
USAGE AREAS
• At the building entrances, stair vestibules.
• At the long halls within the flats.
• At the places required within the flats.
• At the parking garage.
• At the requisite locations within the hotels.
• At the schools, hospitals and oil filing station.
"OFFERS ENERGY SAVING FEATURE''
GENERAL SECURITY CAUTIONS
• Take off the original package and control if there is any damage of transportation and general
view of the product.
• Do not use the product at cross purposes.
• Keep it away from water and moist areas.
• Do not use the product at dusty, dirty and rusty places.
• Do not supply high voltage.
• Do not apply any liquid.
• Protect from any stroke.
• Using 230-240V~ voltage is so dangerous that only the specialist electricians must install
and apply.
CAUTIONS FOR INSTALLATION AND USAGE
• Installing must be carried out professionally in accordance with applicable national wiring and
electrical operating conditions.
• Turn of the network before mounting.
• Do not mount the product near the radiator and moist areas.
• Fix the bulb before operating.
• Use 6A fuse the supply input.
• Factory setting; daylight adjustment is at darkness, time adjustment is at the shortest.
• Setting can be made 10 - 15 second after the releasing of the power.
• Time and daylight setting can be made during the day or night.
• Do not change the time and daylight settings abruptly.
• Do not make a second adjustment before you get a result from the first setting of the time
and daylight.
• After you determine the right setting of the daylight, you can arrange the time as you need.
• The best result for the daylight setting can be obtained by adjusting the minimum. And that
you can find the correct setting for sensitivity incrementally.
• When a cleaning needed for the glass, take of carefully and clean with a dry rag.
• Avoid mounting the detector close to objects that can cause rapid temperature changes such
as heaters, fans, refrigerators and ovents etc, and prevent the detector from point-blank
sunshine.
• It can cause the device operate inaccurately if there is tree, brushes etc. in the coverage area.

SPECIFICATIONS

Operating voltage
: 230-240V~ 50/60 Hz
Detetion angle
: 110°
Mounting hight
: 2.2 m.
Detectio range
: 9 m
Time settings
: 7 sec. ± 3 sec. / 6 min. ± 2 min.
Lighting load
: 283 lm
Protection class
: IP54
Class II
Opt. temperature
: -20 °C ~ +40°C
Detection range is determined at the temperature of +20°C
SETTING
(LUX) Daylight setting
The sensor's response threshold can be infinitely varied from 2-2000 lux.
If you turn the knob anti-clockwise device will operate at dark.
Control dial set clockwise
= daylight operation approx. 2000 lux.
Control dial set anti clockwise = night-time operation approx. 2 lux.
(TIME) (f) Time setting
Light ON time can be adjusted continuously from "7 sec. ± 3 sec. / 6 min. ± 2 min." If you turn
the knob anti-clockwise device will operate at minimum time.
Control dial set to anticlockwise = Shortest time (7 sec. ± 3 sec.)
Control dial set to clockwise= Longest time (6 min. ± 2 min.)
NOTE: Device will automatically make its own offset by checking environment for
approximately 5 minutes after the first installation. After this period device will operate
normally. If you think the device does not operate normal in first installation, please
wait for 5 minutes and start to test again. Be sure that there is no motion by this period.
10210
10210
N
L
L
DETECTING RANGE
Wall
SYSTEM COMPONENTS
(a) Body
(b) Wall mounting hole
(c) Terminals
(d) Screw of fix to glass
(e) Glass
Mount the body indicated at (a) parallell to the wall by mounting holes on product indicated at
(b) with the mounting screws that in included in the package. And then, make the L-N connections
to the connector that is shown at (c). After making the settings according to the room conditions,
mount the plastic glass cover on to the body carefully with the glass screws as indicated at (e)
TROUBLESHOOTING
MALFUNCTION
• Led's are off.
• There is no
electricity on the
device
• Continuously
leds is on
• Change perception
area in device
DETECTION AREA :
Detection area of motion sensors depends on the angle between PIR detector and moving
direction, temperature (power of lamps changes this temperature), mounting style and mounting
place. Temperature is very important for operation for motion sensor like all electronic devices.
Using higher value of loads written on manuals and packages will decrease temprature inside
the device when using Na-De Ceiling Armatures with Motion Sensor. As a result detection range
will decrease and may cause defect of electronic components. Environment temperature will
also cause decrease of detection range. Detection range give is determined at +20°C. If the
weather is hot, it will decrease.
Walking targential to the sensor
(normal detection range)
The maximum detection range can be realized when walking tangential to the sensor (figure1)
When walking directly to the sensor detection range will be low. Because you will not be able
to cut vertical areas. Detection range of 10210 model is 9 m.
GUARANTY
We will remedy defects caused by material flaws or manufacturing faults. The warranty will be
met by repair or replacement at our own discretion. The warranty shall not cover damage to
wear parts, damage or defects caused by improper treatment or maintenance. Further
consequential damage to other object is excluded.
Claims under the warranty will only be accepted if the unit is sent fully assembled and well
packed complete with a brief description of the fault, a receipt or invoice ( date of purchase and
dealer's stamp) to the appropriate Service Center.
info@na-de.com.t • www.na-de.com.tr
(L) = Line conductor
(N) = Neutral conductor
Connect line (L) and neutral (N) to the terminal block.
N
The bulb must be fixed before the electrical connection.
L
Top View
Sensor
110°
(a)
(b)
(b)
(C)
N
L
CAUSE
• Daylight adjustment set to
night-time mode during daytime
operate
• Power switch off or no electricity
• Fuse faulty
• Fuse switch off or fuse faulty
• Connection faulty.
• Continuously movement in
detection zone
• Cars on the streets are being
detected.
• Wind, rain, snow is moving to the
trees & bushes or open windows in
detection zone.
• Sudden temperature changes due
to weather(wind, rain, snow) or the
air expelled from fans.
• Different ambient temperatures.
Figure 1
Walking directly to the sensor
9 m.
(e)
(d)
SOLUTION
• Control daylight setting and
re-adjust
• Check the electricity and power
on.
• Change the fuse.
• Check the fuse if necessary use
a new fuse.
• Check the connection cables.
• Check the detection zone.
• Avert it is being detection.
• Change detection zone, change
site of installation.
• Change site of installation or keep
the reasons away.
• Change site of installation.
(lower detection range)