Initial Operation - American Water Heater 240HX3 Installation Manual And Owner's Manual

On-demand water heater
Table of Contents

Advertisement

INITIAL OPERATION

FOR YOUR SAFETY, READ BEFORE OPERATING
• Check the GAS and WATER CONNECTIONS for leaks before firing unit for the first time.
• Open the main gas supply valve to the unit using only your hand to avoid any spark. Never use tools. If
the knob will not turn by hand, do not try to force it; call a qualified service technician. Forced repair
may result in a fire or explosion due to gas leaks.
• Be sure to check for the presence of leaking gas toward the bottom of the unit because some gases are
heavier than air and may settle towards the floor.
• Check the GAS PRESSURE. Refer to pages 30 and 51.
• Do not try to light the burner manually. It is equipped with an electronic ignition device which automati-
cally lights the burner.
• Check for PROPER VENTING and COMBUSTION AIR to the water heater.
• Purge the GAS and WATER LINES to remove any air pockets.
• Do not use this appliance if any part has been under water. Immediately contact a qualified install-
er or service agency to replace a flooded water heater. Do not attempt to repair the unit! It must be
replaced!
IF YOU SMELL GAS:
• Do not try to start the water heater.
• Do not touch any electric switches; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
WARNING
• If you cannot reach your gas supplier, call the fire department.
• Failure to observe these warnings could lead to fire or an explosion, resulting in severe
injury or death.
the above checks have been completed, please clean filter of
Once
1.
any debris. Refer to page 49 for instructions.
2.
ully open the manual water control valve on the water supply line.
F
pen a hot water tap to verify that water is flowing to that tap,
O
3.
then close the hot water tap.
4.
ully open the manual gas control valve installed.
F
5.
urn on the 120 VAC, 60 Hz power supply to the water heater.
T
NOTE:
To reduce the risk of scalding, install Thermostatic Mixing Valves (temperature limiting valves) at each point of use.
Operation
40
Page
Installation Manual
Initial operation

Advertisement

Table of Contents
loading

This manual is also suitable for:

340hx3540hx3

Table of Contents