Summary of Contents for Azkoyen Hopper U 3030 Series

  • Page 1 Eurocoin Technical Support Docum ent Product Descript ion Azkoyen Hopper U Original Eurocoin Current Dat e of Manufact urer Part Num ber Revision Release Se pt 2 0 0 4 Azkoyen 3030xxxx Rev 1 Docum ent Cont ent Sum m ary Technical Manual www.eurocoin.co.uk...
  • Page 2 Technical Information: HOPPER U U - HOPPER 10095 UK 09 - 2004...
  • Page 3 Technical Information: HOPPER U INTRODUCTION AND DESCRIPTION OF COMPONENTS This manual contains the technical information on the rotating hoppers in the U series. A rotating hopper from the U series is an intelligent mechanism designed for paying out a determined type of coin. It works in combination with another intelligent mechanism that governs it and of which the hopper is part (gaming, vending, parking machines, etc).
  • Page 4 Technical Information: HOPPER U Small hopper Medium hopper Large hopper L=115 mm and 250 coins L=115 mm and 400 coins L=115mm and 600 coins Microprocessor controlled PCB control board. Anti jam and anti span systems. Jams. These hoppers have a current draw detection system to manage the possible coin jams that may occur.
  • Page 5 Technical Information: HOPPER U Two hoppers can be configured in cascade to maximise the use of space within the machine. The configuration of the node addresses is carried out using the dip switches situated on the PCB which is situated on the underside of the hopper, as shown in the illustration.
  • Page 6: Description Of Components

    Technical Information: HOPPER U Hopper cctalk number address When using cctalk protocol the addresses can also be configured by software using Cctalk protocol MDCES commands, reaching a maximum of 253 addressable nodes. DESCRIPTION OF COMPONENTS Coin bay This element of the hopper holds the coins. There are various models with different coin 10095 UK 09 - 2004...
  • Page 7 Technical Information: HOPPER U capacities and sizes. Coin bays Hopper Coin capacity Ø 24 mm €1 €2 Thickness 2.8 mm € cents € cents € cents € cents Small Medium Large 1,100 1,100 Moving flap This element is used to move the coins and dose the flow of coins that reach the extractor disk. Another function is to avoid the pressure of an excessive number of coins on the extractor disk.
  • Page 8 Technical Information: HOPPER U The application of these control systems is not possible in all the hopper models. Refer to the following table: Full hopper detection systems Hopper type Photocells Overflow Scales Small Medium Large Hopper empty detector This system is based on management by an electronic infrared photocell. This system can be applied to all the hopper models.
  • Page 9 Technical Information: HOPPER U emptying the hopper of coins. Extractor disk There are three different coin extractor disks. The three accept the same thickness coins which are between 1.2 mm minimum and 3.5 mm maximum. Disk with 8 ridges and a red pivot: for coins with diameters between 18 and 30 mm. This disk can reach a payout speed of 5.3 coins/second.
  • Page 10 Technical Information: HOPPER U It also guides the coins toward a second hopper when two hoppers are mounted together in the configuration called “cascade”. 10095 UK 09 - 2004...
  • Page 11 Technical Information: HOPPER U WORKING CONDITIONS AND NORMS Optimum results from using this equipment can be obtained by meeting the following requirements: Power the hopper with a transformer that meets the EN-60742 Norm and provides a maximum of 42.5 Vac without load. Install the Discriminator series hoppers with a maximum inclination of +/- 3ºon all axes.
  • Page 12: Cleaning And Maintenance

    Technical Information: HOPPER U CLEANING AND MAINTENANCE The maintenance required for the hopper can be summed up as: - General cleaning of the apparatus after 500,000 coin extractions - It is recommended to clean the coin exit area where the optic sensors are more frequently.
  • Page 13: Dimensions And Volumes

    Technical Information: HOPPER U DIMENSIONS AND VOLUMES Hopper without overflow Hopper L (mm) Small Medium Large Hopper with overflow Hopper L (mm) Medium Large Hoppers mounted in “cascade” 10095 UK 09 - 2004...
  • Page 14 Technical Information: HOPPER U PINOUT Serial communication 10095 UK 09 - 2004...
  • Page 15 Technical Information: HOPPER U cctalk with 3 wires for + and 3 for - 10095 UK 09 - 2004...
  • Page 16 Technical Information: HOPPER U Parallel 10095 UK 09 - 2004...
  • Page 17 Technical Information: HOPPER U Parallel with full and empty sensors 10095 UK 09 - 2004...
  • Page 18 Technical Information: HOPPER U Parallel without full and empty sensors 10095 UK 09 - 2004...
  • Page 19 Technical Information: HOPPER U Parallel (pin 10 is used for the full sensor) 10095 UK 09 - 2004...
  • Page 20 Technical Information: HOPPER U Parallel plug & play 10095 UK 09 - 2004...
  • Page 21 Technical Information: HOPPER U Parallel, plug & play and no empty sensor 10095 UK 09 - 2004...
  • Page 22 Technical Information: HOPPER U Standard CCTALK 10095 UK 09 - 2004...
  • Page 23 Technical Information: HOPPER U Standard cctalk with 2 wires for + and 2 for - 10095 UK 09 - 2004...
  • Page 24 Technical Information: HOPPER U Plug & play. For cigarette vending machines 10095 UK 09 - 2004...
  • Page 25 Technical Information: HOPPER U Brands of the AZKOYEN AZKOYEN MEDIOS DE PAGO S.A. 10095 UK 09 - 2004...