4 Basic operation

Hardware design

4.1
It is recommended to use a DC stabilized power supply. The power supply ripple factor is as small as possible and
the module needs to be reliably grounded;
Please pay attention to the correct connection of the positive and negative poles of the power supply,
reverse connection may cause permanent damage to the module;
Please check the power supply to ensure that between the recommended supply voltage, if exceeding the maximum,
the module will be permanently damaged;
Please check the stability of the power supply. Voltage can not fluctuate greatly and frequently;
When designing the power supply circuit for the module, it is often recommended to reserve more than 30% of the
margin, so the whole machine is beneficial for long-term stable operation;
The module should be as far away as possible from the power supply, transformers, high-frequency wiring and other
parts with large electromagnetic interference;
Bottom Layer High-frequency digital routing, high-frequency analog routing, and power routing must be avoided
under the module. If it is necessary to pass through the module, assume that the module is soldered to the Top Layer,
and the copper is spread on the Top Layer of the module contact part(well grounded), it must be close to the digital
part of the module and routed in the Bottom Layer;
Assuming the module is soldered or placed over the Top Layer, it is wrong to randomly route over the Bottom Layer
or other layers, which will affect the module's spurs and receiving sensitivity to varying degrees;
It is assumed that there are devices with large electromagnetic interference around the module that will greatly
affect the performance. It is recommended to keep them away from the module according to the strength of the
interference. If necessary, appropriate isolation and shielding can be done;
Assume that there are traces with large electromagnetic interference (high-frequency digital, high-frequency analog,
power traces) around the module that will greatly affect the performance of the module. It is recommended to stay
away from the module according to the strength of the interference.If necessary, appropriate isolation and shielding
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
NC
GND
GND
NC
GD02
GD00
MISO/GD01
Output
MOSI
Input
SCK
Input
CSN
Input
GND
ANT
Input/Output
GND
No need to connect
Ground wire, connected to the power reference ground
Ground wire, connected to the power reference ground
No need to connect
CC1101 chip pins (see CC1101 official user manual for details)
CC1101 chip pins (see CC1101 official user manual for details)
SPI master output slave input
SPI master input slave output
Serial Clock Input
SPI Chip select for starting SPI communication
Ground wire, connected to the power reference ground
Antenna, stamp hole(50 ohm impedance)
Ground wire, connected to the power reference ground
E07-400M10S User Manual