14.4

Exchanging the Hard Disks

The hard disk to be inserted must already have an installed operating sys‐
tem, if no external boot medium is connected to the panel PC. In any case,
it is recommended to have a completely installed operating system on the
hard disk to shorten the installation time!
NOTICE
Comply with all ESD protective measures while working with modules and components!
Avoid electrostatic discharges!
1. All required user data as well as the operating system settings of your system are
to be stored either on an external storage medium or via the network connection!
For information on data backup, please refer to chapter "Data backup with Acro‐
nis...." in the project planning manual of the panel PC.
2. Switch off the supply voltage.
3. Wait until the power supply unit switches off automatically after the UPS opera‐
tion.
4. Ensure that no voltage remains in the control cabinet PC. Disconnect the PC
power supply from the X10 connection if required.
5. Remove the five marked housing screws at the housing side, see
tion of the screws of the housing cover" on page
Fig.14-1: Position of the screws of the housing cover
Damages to the device due to electrostatic dis‐
charges!
33:
Bosch Rexroth AG
Maintenance
fig. 14-2 "Posi‐
33/43