Table 7 describes the serial pass-through cabling indicated in Figure 17 on page 27.
Table 7.
Serial pass-through cabling
Cable
1
2
3
4
5
6
7
To configure the serial pass-through, do the following:
1. Set up all the other equipment per the manufacturer's instructions.
2. Wire the system as shown in Figure 17 on page 27.
3. Ensure that the baud rates and ports are the same between the two.
4. Click the Enable radio button on both unit's web page.
5. Enter the IP address of the receiver on the transmitter's web page (Figure 18).
Figure 18. Receiver settings
Description
Composite video cables supplied with SymNet1.
The 4310-0032 cable supplied with the KTD-405 keypad. Wire pin 3 (+ve) to pin 10 of the 20-pin I/O
connector on the SymNet1. Wire pin 6 (-ve) to pin 9 of the 20-pin I/O connector of the SymNet1.
Network interface cabling. Typically a standard CAT-5 patch cable
Standard high quality 75-ohm coaxial cable, BNC to BNC. Connects between the video in connector of the
monitor to the video out connector on the SymNet1s video adapter cable.
The 4310-0032 cable supplied with the ProBridge. Wire pin 3 (+ve) to the RS422 A terminal on the dome
interface board. Wire pin 6 (-ve) to the RS422 B terminal on the dome interface board.
Standard high quality 75-ohm coaxial cable, BNC to BNC. Connects between the video out connector of the
dome's interface board to the video input connector on the SymNet1s video adapter cable.
The RJ45 control cable supplied with the KTD-405 Keypad. You can also use a standard straight-through
CAT-5 patch cable.