Page 1
Failure to follow any of these instructions could result in bodily harm or death, and could void product warranties. LogiCO2 International AB, its affiliates and third party providers assume no responsibility for claims arising from improper or careless use or handling...
Important Safety Information! When testing a Danger Zone, the Scout should be placed into the LogiCO2® foam ball provided with the Scout The Scout is an instrument that measures the CO2 (below mentioned the “Foam Ball”) and rolled into concentration in the ambient air. Through Bluetooth the...
Page 3
It works together with a smartphone app Mode*”. To start the Scout for the first time, shortly called “LogiCO2-Scout” (iPhone or Android) (the “App”), in connect it to a USB charger with the enclosed cable. The which the current CO2 concentration is displayed on the App shows the battery charging status.
Page 4
Pic.1: Tap on “Scan devices”. Pic.2: Tap on “LOGICO2-x” to connect. If more than one Scout is within the smartphones range, they will all be visible in the “Scanning for devices”-list. To be sure that you connect to your own Scout, tap on “Check”. If it is “your Scout”, the LED on it will flash blue twice.
Page 5
Connection Trouble Fresh Air Testing If there are problems connecting the Scout to your WARNING! Always conduct a fresh air test, and smartphone, turn the Scout off and on to clear its calibrate the Scout if necessary, prior to each “connection memory”.
Android and iPhone: Tap on the Gear in the upper right corner of the App and then tap on Calibrate. Follow the fresh air calibration instructions in the App. WARNING! Do not calibrate the LogiCO2-Scout indoors. Always conduct calibration outside in fresh air.
Page 7
How to Conduct a CO Danger Zone 4. Ensure that the App shows reading. Testing 5. Gently role the Foam Ball into the Danger Zone. 1. Turn on the Scout and connect to a smartphone. WARNING! Be sure to roll the Foam Ball along Double check that the LED light is blue.
Page 8
Dangerously High CO Concentration Pre-Alarm: Open doors and windows as much as possible. Call service technician. When the CO2 concentration is over 3%, the Scouts red LED alarm indicators will start flashing and audiable IMPORTANT! A service technician should only enter the alarm will activate, the smartphone will start emitting Danger Zone under the supervision of another person.
Page 9
TWA (Time Weighted Average) Monitoring Android iPhone It is unhealthy for humans to be exposed to more than the Hygienic Limit Value of CO2 during an 8-hour working day. The Hygienic Limit Value exposure of CO2 over 8 hours/day in the USA and most other countries is 0,5% or 5000 ppm CO2.
Technical Specifications Product features Operating Principle: Non-dispersive infrared (NDIR) LogiCO2-Scout Glow Measurement range: 0-6% volume CO2 Battery information Powered: Li-Ion 3,6V, 1150mAh Operating time: Approx. 12h Charging: With a USB - Micro USB cable to a normal smartphone charger Charging time: Approx.
Page 12
Scan the QR-code below to download the free companion app to the LogiCO2 Scout Or search your appstore for the application "LogiCO2 Scout" by LogiCO2 Manufactured by: LogiCO2 International AB P.B. 9097 E-mail: info@logico2.com SE-400 92 Gothenburg, Sweden Web: www.logico2.com...