Rockwell Automation Allen-Bradley Dynamix 2500 User Manual

Bump test extension module for the data collector

Advertisement

Quick Links

User Manual
Bump Test Extension Module for the Dynamix 2500
Data Collector
Catalog Number 1441-DYN25-MBMP

Advertisement

Table of Contents
loading

Summary of Contents for Rockwell Automation Allen-Bradley Dynamix 2500

  • Page 1 User Manual Bump Test Extension Module for the Dynamix 2500 Data Collector Catalog Number 1441-DYN25-MBMP...
  • Page 2 In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
  • Page 3: Table Of Contents

    Delete Bump Test Files ......... . . 28 Index Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 4 Table of Contents Notes: Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 5: Optional Extension Modules

    The RUCD test records and analyzes data from intermittent events and transient vibration signals from non-steady state machines. Additional Resources on page 6 for a listing of available publications. (1) This is an activation license for the Dynamix 2500 data collector. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 6: Additional Resources

    Provides declarations of conformity, http://www.ab.com certificates, and other certification details. You can view or download publications at http://www.rockwellautomation.com/literature. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 7: Install Extension Modules

    1. Open the base cover at the bottom of the Dynamix 2500 data collector. 2. Place the extension module Secure Digital (SD) card contact-side-up into the unit until it is firmly seated in place. 3. Close the base cover. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 8 6. Press 0 (Shift) to display the second set of functions. Extension Manager The Extension Manager function remains on the screen for about three seconds after releasing the 0 (Shift). 7. Press F1 (Extn Mgr). Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 9 9. Press F2 (Install) to install the new extension module. When the installation is complete, a confirmation prompt appears. 10. Press F4 (OK). The new extension module appears in the list. 11. Press F4 (Esc) to exit the Extension Manager screen. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 10: Uninstall Extension Modules

    This screen lists the extension modules currently installed and the on the unit. 3. Select the extension module you want to uninstall and press F3 (Select). F3 (Select) toggles the selection on and off. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 11 6. Press F2 (Yes) to uninstall the extension module. 7. Press F4 (Esc) to exit the Extension Manager screen. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 12: Manage Extension Modules

    The F2 function key toggles between Hide and Show depending on if the selected extension module is hidden. You have to exit and re-enter the Extension Manager after hiding an extension module to have the Show function appear. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 13: Extension Module Battery Status Indicators

    Table 1 - Extension Module Battery Icon Descriptions Battery Icon Meaning Battery status is good: >30% life remaining. Battery status is low: >10% life remaining. Battery status is very low: <10% life remaining. Battery is charging. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 14 Chapter 1 Installing Optional Extension Modules Notes: Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 15 The Bump Test identifies a structure’s resonant modes and provides you with the opportunity to change the resonance frequency to reduce or eliminate damaging vibration levels. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 16: Set Up Bump Test Measurements

    Save – Saves the current bump test settings. Enter a filename to identify the bump test settings. Start – Take bump test data using the current settings. Back – Returns you to the Bump Test menu. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 17 Displays high-pass filter settings. 2 Hz (default) Off, 0.36 Hz, 1.1 Hz, 2Hx, 10 Hz, 70 Hz Freq Range (Fmax) The FFT upper full-scale 1000 Hz (default) frequency, up to 40,000 Hz (2,400,000 CPM). Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 18 Logarithmic Logarithmic dB 6. Press F2 (Save) to name and save the current settings for future recall. 7. Press F3 (Start) to begin collecting data. The Bump Test – Taking Data screen appears. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 19: Collect Bump Test Measurements

    Start function. Press F3 (Start) to start collecting data again. • The Left and Right arrows move the cursor across the x-axis to determine the natural frequencies. • The Up and Down arrows change the scale on the y-axis. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 20: Save A Bump Test Setup And Measurement

    .csv files can be viewed with the Microsoft Excel software. Follow these steps to save a file. 1. Take a reading. 2. Press F2 (Save). The Bump Test - Save Data screen appears. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 21: Recall A Setup

    Follow these instructions to recall a Bump Test setup. 1. Connect the transducer to the Dynamix 2500 data collector. 2. Attach the transducer to the machine case or structure. 3. Select Bump Test on the Main Menu and press Enter. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 22 5. Select the filename (test settings) that you want to recall (reload) and press F3 (Open). The Bump Test - Setup screen appears. 6. You can edit the settings or start collecting more data. Set Up Bump Test Measurements on page Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 23: Review Bump Test Measurements

    3. Press F2 (Prev) and F3 (Next) to display the previous or next measurement. 4. Press F1 (Print) if you what to create a .bmp file that is stored on the SD storage card or internally. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 24 To delete previously saved bump test data, select the file and press 0 (Shift) and then F4 (Delete). 6. Select the file that you want to review and press F3 (Open). Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 25: Save Files To Your Computer

    2. From the File menu, select Explore. 3. From the Windows Explorer window, copy the stored measurement files (.csv files) from the data collector’s Internal Disk/Analyzer folder to a folder on your computer. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 26: Back Up Your Files

    2. From the Bump Test - Review Data screen, use the Up and Down arrows to select a measurement for backup, or select the – all – option to back up all measurments. 3. Press 0 (Shift). The Backup function appears. 4. Press F1 (Backup). Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 27 All selected measurement files are copied to the SD card and a Backup Complete message appears. 5. Press F2 (OK) to return to the Review Data screen. 6. Remove the card and store in a safe place. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 28: Delete Bump Test Files

    If you want to delete a file on the storage card either open the folder and delete the file or you can use the ActiveSync software. Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 29 3. Use 0 (Shift) on any Recall screen to display the delete function. 4. Select a file and press 0 (Shift). 5. Press F4 (Delete). The deleting file popup appears. 6. Press F2 (Yes) or F3 (No). Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 30 Chapter 2 Bump Test Extension Module Notes: Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 31 7 USB cable 25 uninstall 7 extension module hide and show 12 license 11 vibration 15 not visible 12 X-axis 17 fatigue 15 FFT 17 filter 17 frequencies 15 y-axis 18 frequency 19 Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 32 Index Notes: Rockwell Automation Publication 1441-UM002A-EN-P - May 2011...
  • Page 34 Rockwell Automation representative. New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures.

This manual is also suitable for:

1441-dyn25-mbmp

Table of Contents