Download Print this page
CAT Pumps 7590 Datasheet

CAT Pumps 7590 Datasheet

Pressure sensitive multiple gun regulating unloaders

Advertisement

Quick Links

FEATURES
Maintains full system pressure while running
l
in by-pass without full load on pump.
Offers pump protection against pressure
l
fluctuations and system changes.
Minimum pressure fluctuations with alternating
l
use of multiple guns.
Easy external pressure adjustment with locking
l
nut to prevent over pressure.
Lightweight flow through design for compact
l
installation.
All High Pressure Systems require a primary pressure regulating device (i.e. regulator,
unloader) and a secondary pressure relief device (i.e. pop-off valve, relief valve). Failure
to install such relief devices could result in personal injury or damage to pump or
property. CAT PUMPS does not assume any liability or responsibility for the operation
of a customer's high pressure system.
Read all CAUTIONS and WARNINGS before commencing service or operation of any
high pressure system. The CAUTIONS and WARNINGS are included in each service
manual and with each Accessory Data sheet. CAUTIONS and WARNINGS can also be
viewed online at www.catpumps.com/cautions-warnings or can be requested directly
from CAT PUMPS.
Pressure Sensitive
Multiple Gun
Regulating Unloaders
Models
SPECIFICATIONS
7590
MODEL
Flow Range .................................................. 10-52 gpm
Pressure Range . .......................................400-2175 psi
7592
MODEL
Flow Range .................................................. 10-52 gpm
Pressure Range . .......................................450-2500 psi
COMMON SPECIFICATIONS
Inlet Port (Flush Back) .................................... 1" NPTF
Discharge Port (Extended Front) ............... 1" NPTF
By-Pass Port (Flush Bottom) ........................ 1" NPTF
Maximum Operating Temperature:
Standard Buna o-rings . .......................................140°F
Standard Buna o-rings (intermittent) ...........195°F
Optional FPM o-rings . .........................................240°F
Weight . ................................................................4.46 lbs.
Dimensions . ................................. 8.85 x 5.08 x 1.625" (225 x 129 x 41 mm)
Unloader is stamped with a European safety pressure. Use only at above
specifications to assure proper unloader life and performance.
For Relief Valve version add .100 to unloader model number.
7590
7592
U.S. Measure
Metric Measure
(38-200 lpm)
(30-150 bar)
(38-200 lpm)
(31-175 bar)
(1" NPTF)
(1" NPTF)
(1" NPTF)
(60°C)
(90°C)
(116°C)
(2.02 kg)

Advertisement

loading
Need help?

Need help?

Do you have a question about the 7590 and is the answer not in the manual?

Questions and answers

Summary of Contents for CAT Pumps 7590

  • Page 1 (i.e. pop-off valve, relief valve). Failure to install such relief devices could result in personal injury or damage to pump or property. CAT PUMPS does not assume any liability or responsibility for the operation Optional FPM o-rings ..........240°F (116°C)
  • Page 2 Read all CAUTIONS and WARNINGS before commencing service or operation of any high-pressure system SELECTION OPERATION This is a pressure sensitive regulating unloader. Designed for systems This pressure sensitive regulating unloader holds established system with single or multiple pumps, solenoid (gate) valves, nozzles, standard or pressure in the discharge line when the trigger gun is closed or solenoid “weep” guns. (gate) valve is closed or the nozzle is clogged, thus by-passing all unrequired flow. Squeezing the trigger gun or opening the solenoid Note: For multiple pump systems, it is best to use a pressure regulator (gate) valve will close off the by-pass and return to established system...
  • Page 3 Read all CAUTIONS and WARNINGS before commencing service or operation of any high-pressure system SERVICING Reassembly: CAUTION: Before commencing with service, shut off drive (electric motor, gas or diesel engine) and turn off water supply to pump. Relieve all 1. Lubricate and install o-ring on outside diameter of seat and press seat discharge line pressure by triggering gun or opening valve in discharge squarely into position in the lower body.
  • Page 4 DESCRIPTION 402 429 — NBR O-Ring, Piston 33089 NY Handle, Adjusting w/Screw 403 39061 STZP Adjuster, Pressure (M10x42) 430 — PTFE Back-up-Ring, Piston 404 — STZP Nut, Hex Locking (M10) (7590) 431 — NBR O-Ring, Piston Retainer 406 — AL Spacer (7592) 435 32774 S Valve 407 39062 BB Retainer, Spring 436 32775 S...

This manual is also suitable for:

7592Pu7592