7 Installing the accumulator
7.4
1. The process of bringing the additional cylinder into the building and installing it is
the same as that for all other types of the accumulator.
When installing and setting up the additional cylinder, the same height must be
attained as for the adjacent accumulator.
Distance between accumulator and additional cylinder
2. Installation is reduced to installing the insulation and connection to the accumu-
lator.
3. See Section Installing the Insulation
Installing the Additional Cylinder
Model size of the accumu-
lator and additional cylin-
der
600 litres
800 litres
1000 litres
Distance between centre
of accumulator and cen-
tre of additional cylinder
1080 mm
1120 mm
1120 mm
Space between the insula-
ted cylinders.
approx. 150 mm
approx. 80 mm
approx. 80 mm
Installation manual