  • Page 2: Table Of Contents

    Content 1. General ........................... 3 1.1 Introduction of ATEX ..........................3 1.2 Zone Classification ..........................4 1.3 Gas Group ............................... 4 1.4 ATEX code description .......................... 6 2. Specifications and description of design ................7 2.1 Compressor Nomenclature ........................7 2.2 Compressor outline..........................
  • Page 3: General

    1. General 1.1 Introduction of ATEX ATEX is an acronym of “Atmosphéochres Explosives” from French. This includes two European Union (EU) directives which regulate the manufacture, selection and usage of equipments in dangerous zone and has become a compulsory act between members of EU since July 2003.
  • Page 4: Zone Classification

    management system, and each product can reach the same standard as an EU model tested sample. According to different conditions of conformity assessment the appendix of ATEX 2014/34/EU also regulates corresponding QA requirements. The confirmation of requirement of the above mentioned QA system is supervised by EU designated authorities, and the so called QA system is not only the field covered by ISO 9001.
  • Page 5 (>450 (>300 (>200 (>135 (>100 (>85 Methane II A Acetic acid Ethanol Gasoline Acetaldehyde Ammonia 1,4 Butane Diesel Benzene Butanol Kerosene Propanone Fuel oil Ethane Hexane Ethyl acetate Carbon monoxide Methanol Propane Methylbenzene II B Coal gas Ethylene Diethyl ether II C Hydrogen Acetylene...
  • Page 6: Atex Code Description

    1.4 ATEX code description II 2 G c IIB T4 II 2 G Ex d IIB T4 Gb...
  • Page 7: Specifications And Description Of Design

    2. Specifications and description of design 2.1 Compressor Nomenclature R C 2 – x x x x Explosion proof products Displacement at 50Hz RC model 2 version 2.2 Compressor outline RC2-100ExP/140 ExP A/B...
  • Page 8 RC2-180 ExP A/B RC2-200 ExP A...
  • Page 9 RC2-200 ExP B RC2-230 ExP A/B UNIT SI: mm Imperial: (in)
  • Page 10 RC2-260 ExP A/B UNIT SI: mm Imperial: (in) RC2-300 ExP /320 ExP A...
  • Page 11 RC2-300 ExP /320 ExP B RC2-310 ExP A/B...
  • Page 12 RC2-340 ExP /370 ExP A RC2-340 ExP /370 ExP B...
  • Page 13 RC2-410 ExP A/B RC2-470 ExP A...
  • Page 14 RC2-470 ExP B RC2-510 ExP A/B...
  • Page 15 RC2-550 ExP A RC2-550 ExP B...
  • Page 16 RC2-580 ExP A/B RC2-620 ExP A/B...
  • Page 17 RC2-710 ExP A RC2-710 ExP B...
  • Page 18 RC2-790 ExP A RC2-790 ExP B UNIT: SI: mm Imperial: (in)
  • Page 19 RC2-830 ExP A RC2-830 ExP B...
  • Page 20 RC2-930 ExP A R2C-930 ExP B...
  • Page 21: Compressor Construction

    2.3 Compressor construction RC2-100ExP, RC2-140ExP, RC2-180ExP Construction Item Description Item Description Item Description Item Description Compressor casing Oil separator cartridge Discharge fixed ring Refrigeration Lubricant Motor casing Piston Disc spring Suction flange Oil separator Piston spring Bearing lock nut Discharge flange Motor rotor assembly Piston rod Male rotor...
  • Page 22 RC2-200Exp, RC2-230 ExP RC2-260 ExP, RC2-300 ExP, RC2-310 ExP, RC2-340 ExP, RC2-370 ExP, RC2-410 ExP, RC2-470 ExP, RC2-510 ExP, RC2-580 ExP Construction 19 20 Item Description Item Description Item Description Item Description Compressor casing Piston Disc spring Suction flange Motor casing Piston spring Bearing lock nut Discharge flange...
  • Page 23 RC2-550ExP, RC2-620ExP Construction Item Description Item Description Item Description Item Description Compressor casing Piston Disc spring Suction flange Motor casing Piston spring Bearing lock nut Discharge flange Oil separator Piston rod Male rotor Cable box Motor rotor assembly Bearing seat’s cover plate Suction bearings Power bolt Suction bearings inner/outer...
  • Page 24: Applicable Refrigerants For Compressors

    2.4 Available refrigerants for compressors Available refrigerants for Hanbell compressors are included A1, A2, A3 in ASHRAE 15, and the refrigerant of working conditions corresponding to the use of pressure must not exceed 28kg/cm G. Please contact Hanbell directly if refrigerant is excluding on the list of ASHRAE 15 or not included in the scope of the refrigerant A1 to A3.
  • Page 25: Mcc And Lra

    COMPRESSOR MOTOR Hydrostatic Lubricant Model Displacement Rated Nominal Voltage Pressure WEIGHT MODEL Cap. Control (%) charge Heater Type 60 / 50Hz Speed Type Starting Insulation Protection Test 60 / 50Hz STEP STEPLESS 60Hz 50Hz 60Hz 50Hz Kg/cm2G RC2-580ExP 702/583 35, 50, 75, 100 35~100 RC2-620ExP 745/619...
  • Page 26 Refrigerant : R134a (PWS) 50Hz 60Hz Unit: Ampere Model 380V 400V 415V 208V 220V 230V 380V 440V 460V 480V 575V Model Type RC2-100ExP RC2-140ExP RC2-180ExP RC2-200ExP RC2-230ExP 1075 1030 RC2-260ExP 1075 1030 RC2-300ExP 1325 1230 1135 RC2-310ExP 1325 1230 1135 RC2-340ExP 1450 1335...
  • Page 27: Certification Marking

    400 N-m Table 2.1 cable glands and plugs tightening torque Hanbell selection software provides working current and MCC based on the working condition, which can be the reference for selecting electric wiring, magnetic contactor, and fuse. The anti-loose connector can prevent the compressor from sudden motor trip due to motor protector error.
  • Page 28: Int69Hby Control Module And Ptc Temperature Sensor

    The Ex cable entry of cable box must installed at least by ATEX certified cable glands. It is required to ensure that all bolts, plugs and cable glands are sealed in Ex cable box to avoid malfunction. ※ Sealant can be used LOCTITE 554 or similar nature of glue, but according to EN 60079-14 standard can’t using the tape seal.
  • Page 29: Oil Heater

    Alarm lamp for this protector is required to be embedded on control panel as indicator. Any intention to short controllers for starting of compressors is prohibited. It is beyond Hanbell’s warranty of compressors if there is any action above mentioned found.
  • Page 30: Oil Level Switch

    In addition, Hanbell also offers 250W oil heater to keep adequate lubricant oil temperature for large external oil separator and applications in areas with low ambient temperature. Specification: 250W; 110V or 220V; IP 54; Outer diameter of cable: 6~8mm Note: If compressor is installed in low ambient temperature, it is recommended to insulate oil separator against cold ambience.
  • Page 31: Solenoid Valve

    Note: Before using oil drain valve, the compressor must be switched off and the refrigerant must be recovered completely to avoid dangerous leakage of refrigerant which threats the environment. 2.13 Solenoid valve Figure Solenoid valve Degree of protection IP 67 -40℃~+65℃...
  • Page 32 Percent voltage unbalance = 100 x NEMA states that poly-phase motors shall operate successfully under running conditions at rated load when voltage unbalance at the motor terminals does not exceed 1%. Furthermore, operation of a motor with over 5% unbalance is not recommended for it probably results in motor damage.
  • Page 33: Lubricants

    To solve this problem, use of oil heaters can warm up oil before starting. If the compressor operates under critical operating conditions, an extra oil cooler is required – please refer to Hanbell selection software for the required capacity and oil flow of the extra oil cooler. High-viscosity oil is recommended to apply in high operating conditions because high discharge temperature will make viscosity of oil lower.
  • Page 34: Lubricants Table

    KOH/g COPPER STRIP − − − − 100℃/3hr − − − − MOISTURE − − − − ℃ FLOC POINT DIELETRIC STRENGTH − − − 46.6 2.5mm Note: For other applicable oil types, please consult HANBELL firstly for approval.
  • Page 35: Pre-Cautions Of Changing Oil

    Check acidity of oil after 72 hours of operation and then change it again until acidity of oil becomes normal. 5. Please contact Hanbell local distributors/agents for selection of oil. 3.3 Oil change 1.
  • Page 36: Compressor Handling And Installation

    4.1 Compressor lifting Each HANBELL screw compressor has been carefully tested at the factory and every precautionary measures have been taken to make sure that compressors will keep in perfect condition when reach customers’ work. After the compressor arrives at your warehouse, please check if its crate is kept in good condition and check all the compressor accessories with shipping documents to see if there is any discrepancy.
  • Page 37 If a large-caliber copper tube is not easily accessible and a steel tube is used instead in suction port, Hanbell also recommends the use of a copper tube in discharge port to best minimize abnormal vibration and noise.
  • Page 38: Compressors Accessories

    Note: The accessory table is just for reference only. Actual specification and accessories enclosed might vary with different quotation and agreement respectively. If any optional accessory is required and out of above mentioned standard accessory, please contact Hanbell for detailed specification and price.
  • Page 39 Suction and discharge check valve Hanbell standard check valve (vertical type) is gravity-driven with characteristics of large flow volume and low pressure differential. After shut-down of compressor, Teflon taper guider inside can simultaneously seal up the precisely machined base of check valve by gravity force to effectively prevent return of high-pressured gas to compressor.
  • Page 40 Note: The above table lists specification of standard bushing for every model of Hanbell compressors. Their dimensions correspond to flange bushing dimensions and the table below. If bushing dimensions are not indicated in purchasing order, Hanbell will provide standard type. Suitable piping of customers’ choice is also shown in the table below. If non-standard bushing is needed,...
  • Page 41 141.3 f. Suction and discharge stop valves For maintenance and service of compressor, it is recommended to install the suction and discharge stop valves. Please refer to following detail of Hanbell stop valves. Stop Valve Size Stop Valve Size Model...
  • Page 42: Operation And Maintenance

    10% to the rated voltage. motor between phase to phase and Standard voltage is 220V. Maximum voltage is 230V. phase to ground. If there is other demand, contact HANBELL. Power terminals and wire cables’  Ω Insulation resistance value should be above 5M terminals connection.
  • Page 43 20K above the saturated condensing temperature and the suction vapor superheat should be within 10K to the saturated evaporating temperature. i. The whole plant, especially the pipelines and capillary tubes must be checked for abnormal vibrations. Please contact HANBELL or local distributor if any abnormal vibrations or noise found while compressor is running.
  • Page 44: Regular Check

    5.2 regular check a. To avoid refrigerant leakage, Hanbell strongly recommends using a gas detector and refer to ASHRAE 15 regarding standard leakage rate. b. Check whether clear frozen oil. 5.3 Troubleshooting The table below shows some problem that might encounter in the jobsite during commissioning or upon operation of compressor.
  • Page 45: Compressor Checking List

    HANBELL screw compressor or it should be a Service Engineer from HANBELL. 5.4 Compressor checking list Please fill out the compressor checking list and send it to Hanbell, if any failure of compressor happened. Hanbell will reply and suggest the solution to resolve the failure.
  • Page 46: Warranty

    18 months from the original date of sales by HANBELL or designated sales agent, whichever comes first.