Connecting The Electrical Control Panel To A Power Source - Graco Therm-O-Flow 243698 Instructions Manual

Table of Contents

Advertisement

Installation
Connecting the Electrical
Control Panel to a Power Source
ELECTRIC SHOCK HAZARD
Do not connect the electrical control panel to
a power source unless you are a trained
professional. Failure to follow standard
procedures or to observe the necessary
precautions could result in serious bodily
injury or equipment damage.
F
. 3
IG
8
WARNING
Installation
Have a trained electrician connect the electrical control
panel (Fig. 3) to a grounded electrical source that has 
the required service ratings:
If power and grounding connections are not done
properly, the equipment will be damaged and the
warranty will be voided. Check the label on the
control box for the proper voltage.
AC
Panel Voltage
220/240
To connect the control panel to the electrical source:
1. Locate the opening in the control panel's bottom
housing for the conduit that will enclose the wire
from the facility's power source. The hole diameter
is .804" (20 mm) and includes a cord strain relief for
cable diameters from .236" (6 mm) to .472" (12
mm).
2. Thread the wire from the power source into the con-
trol panel housing, and then connect the power
source wires to the appropriate terminals on the
panel. See Electrical Schematics beginning on
page page 19.
CAUTION
Hz
Phase
Full Load Amps
50/60
1
15.5A - 4-Zone
Control (243699)
11.0A - 2-Zone
Control (243698)
309213G