Automated Logic MX16160 Technical Instructions

Automated Logic MX16160 Technical Instructions

Advertisement

Quick Links

Technical Instructions
MX1 6 1 60
Using the MX16160 2
Specifications 3
Mounting 3
Addressing 3
Power Wiring 3
Inputs 4
Digital Outputs 5
Channel Numbers 6
Troubleshooting 7
LEDs 7
Protection 7
Production Date 7
Automated Logic Corporation • 1150 Roberts Blvd. • Kennesaw, GA 30144 • 770/429-3000 • 770/429-3001 Fax •
www.automatedlogic.com • Copyright 2000 Automated Logic Corporation. All rights reserved. Automated Logic, the
Automated Logic logo, SuperVision, Eikon, Alert, and InterOp are registered trademarks of Automated Logic
®
Corporation. BACnet
is a registered trademark of ASHRAE. All other brand and product names are trademarked by
their respective companies.

Advertisement

loading
Need help?

Need help?

Do you have a question about the MX16160 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Automated Logic MX16160

  • Page 1 Protection 7 Production Date 7 Automated Logic Corporation • 1150 Roberts Blvd. • Kennesaw, GA 30144 • 770/429-3000 • 770/429-3001 Fax • www.automatedlogic.com • Copyright 2000 Automated Logic Corporation. All rights reserved. Automated Logic, the Automated Logic logo, SuperVision, Eikon, Alert, and InterOp are registered trademarks of Automated Logic ®...
  • Page 2 NOTE This equipment has been tested and a piece at a time. By attaching the MX16160 found to comply with the limits for a Class A expander to M or Mcpu controllers, your...
  • Page 3 4. Apply power to the transformer. The MX16160 uses a rotary switch to assign the module’s expander number. If the 5. Make sure that 24VAC is present at the module’s expander address is three, set the module’s power input terminals.
  • Page 4 46 meters Inputs The MX16160 module has sixteen universal 1. Be sure the MX16160’s power is off before inputs to accept the types of signals listed wiring any inputs or outputs. below. Refer to Table 1 for information about 2.
  • Page 5 81- 96) normally closed, according to the jumper setting. Be sure the MX16160’s power is off before wiring any inputs or outputs. Connect the Revised 9/13/00 • MX16160 © 2000 Automated Logic Corporation...
  • Page 6 Gain The following tables show the valid channel -17° to 213° F 0.00 15.88 Thermistor numbers for each point on the MX16160. -27° to 100.6° C 0.00 15.69 Enter the channel number, offset, and gain for UI 1 0 to 20mA mA or Volts §...
  • Page 7: Production Date

    Protection UI 11 0 to 20mA mA or Volts § § 0 to 5V The MX16160 module is protected by internal Digital solid state Polyswitches on the incoming -17° to 213° F 0.00 15.88 power. These Polyswitches are not Thermistor -27°...