Maxwell MW-3554 W Manual Instruction page 8

Ultrasonic air humidifier
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7
ENGLISH
OR HOUSEHOLD USAGE ONLY
BEFORE USING THE UNIT FOR THE FIRST TIME
• Unpack the unit and remove the packing materials. Examine the unit for damages. Do not switch
on the unit if there are any damages in it.
Note:
− if the unit was subjected to negative temperatures, before switching it on for the first
time, keep it at room temperature for 30 minutes.
− use the unit at +5 - +40°С temperature, and relative humidity less than 80%.
− water temperature should not exceed +40°С.
• Before switching on the unit, make sure that the voltage of the electric network corresponds to the
operating voltage of the unit.
• Place the unit on the flat, moisture-resistant surface.
Note:
− Because of the unit design peculiarities it is possible that condensation water drops ap-
pear on the unit body and the surface around it. This is not a malfunction. Place the unit on
a higher surface so that the generated steam is dispersed with the air flow.
Using the ultrasonic air humidifier
1. Remove the lid (1) from the water tank (2).
2. Remove the water tank (2) from unit.
3. Turn over the tank (2); unscrew the lid (4), by turning it anti clockwise.
4. Fill the water tank (2) with necessary quantity of water and screw the lid (4), by turning it clock-
wise.
Note: You can determine amount of water in the water tank (2) with the help of the transpar-
ent window (3).
5. Set the filled tank (2) on the body of the unit.
6. Insert the plug into the socket.
7. Switch on the unit, setting the switch (8) in the position «I», the indicator (7) will light green.
8. Regulate steam intensity by turning the regulator (6).
9. If there is no water in the water tank (2) the indicator (7) will light red.
10. Set the switch (8) to the "0" position, and take the plug out of the socket. Fill the tank (2) with
water and set the filled tank on the body of the unit and switch it on.
11. Set the switch (8) to the "0" position, and take the plug out of the socket.
CLEANING AND CARE
Warning: Always switch off and unplug the unit before cleaning.
Hard water causes appearance of scale on the "sprayer"(5) and in the operating chamber; it leads to
improper operation of the unit and appearance of white deposit on the interior objects. To avoid it:
− use boiled water or water, which stood for some time, water, purified by filter or distilled water;
− clean the operating chamber (5) weekly;
− change water in the water tank (2) more often.