Komatsu PC20R-8 Shop Manual page 76

Hydraulic excavator
Hide thumbs Also See for PC20R-8:
Table of Contents

Advertisement

3) When the control valve is being operated and the demand flow for the actuator becomes greater than the pump
discharge from the minimum swash plate angle, the flow of the oil out, to tank circuit T is shut off, and all of pump
discharge amount Q flows to the actuator circuit.
S
1
OPERATION
Control valve operated
. When the control valve is operated to a larger
stroke, LS pressure P
area S3 at the right end of spool (1).
When this happens, the area of the opening of the
control valve spool is large, so the difference be-
tween LS pressure P
sure P
is small.
P
. For this reason, the difference in pressure between
pump discharge pressure P
does not reach the load of spring (2) (19.69.8 bar
2
(2010 kg/cm
)), so spool (1) is pushed to the left
by spring (2).
10-58
1
P
A
T
is generated and acts on
LS
and pump discharge pres-
LS
and LS pressure P
P
P
P
2
. As a result, pump circuit P
shut off, and all the pump discharge amount Q
flows to the actuator circuit.
LS
B
LS
T
and tank circuit T are
P
PC20R-8 PC27R-8
S
S
3
2
RKP00740

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc27r-8F30791F31103