Download Print this page

G-Fittings 45.100x.090.12 Quick Start Manual page 4

Glass door system

Advertisement

Available languages

Available languages

1. Set up closing force
2. Activate Hold-Open function
3. Adjust Hydraulic buffer
Set up self-closing power. Only adjust the power adjuster of H-S & S-O
1. How to decide the self -closing power setting:
1.1. H-S hinge includes one power adjuster & S-O hinge includes one power adjuster.
You can find them following the S-hinge code.
1.2. Each adjuster includes N-7 setting value. N (Neutral) is out of the box setting,
without closing force. Keep this setting during hinge installation. From 0-7, one
setting value provides 15 pounds (7 kg) of closing force.
1.3. Example:
(Try to set the values evenly)
HS
4
5
2. How to increase or decrease power setting.
2.1. To increase power: adjust the power adjuster to higher number.
2.2. To decrease power: press down the adjuster and turn to lower number.
3. Set up closing power to different angles
3.1. Ensure the hinge can close door from 20°, 60°, 90°.
3.2. The door may slam at this stage. Keep going. Just make sure the door could close at
20°.
Please follow the steps in correct order
S-O
Total Force
135 pounds (9 x 15
5
pounds) 63 kg (9 x 7 kg)
165 pounds (11 x 15
6
pounds) 77 kg (11 x 7 kg)

Advertisement

loading