1. Precautions and Safety Warnings
Please read this manual entirely before using your
MT315–101. You can download a full version of this
manual at www.altinex.com. These instructions are to
ensure the reliable operation of your switcher and to
prevent fire and shock hazards. Please read them
carefully and heed all warnings.
1.1 General
Qualified Altinex service personnel or their authorized
representatives must perform all service.
1.2 Installation Precautions
To prevent fire or shock, do not expose this unit to water
or moisture. Do not place the MT315–101 in direct
sunlight, near heaters or heat-radiating appliances, or near
any liquid. Exposure to direct sunlight, smoke, or steam
can harm internal components.
Handle carefully; dropping or jarring can cause damage.
Do not pull any cables attached to the MT315–101.
2. Installation Procedures
Note:
Download and read the entire online manual to become familiar with the MT315–101 and for detailed installation instructions
and configuration details.
Step 1: Turn off power to the MultiTasker enclosure.
Step 2: Remove a slot cover to make room for the MT315–101.
Step 3. Slide the MT315–101 into the enclosure making note of the slot number. This is needed for control.
Step 4. Secure the card to the enclosure using the thumb screws attached to the card.
Step 5. Restore power to the enclosure and wait for the system to initialize. Once ready, press the button on the enclosure front panel
to verify the new card is recognized.
Step 6. Connect any 2-wire conductor, up to 984 ft (300 m), between the MT315–101 transmitter and a compatible receiver;
MT315-102 or TP315-102.
Step 7. On a LAN, the enclosure IP can be discovered via a UDP broadcast of "?Altinex" to port 30305.
3. Warranty and Return Policies
Please visit the Altinex website at
please complete a RMA (return material authorization) form by clicking the Warranty link located on the bottom of the Altinex
homepage. Once completed, please email the form to support@altinex.com.
400-0663-001
HDMI OVER ANYWIRE TX
®
for demanding audiovisual
www.altinex.com
for details on warranty and return policies. In the case of a unit needing repair,
1.3 Cleaning
Clean the MT315–101 with a dry cloth only. Never use
strong detergents or solvents such as alcohol or thinner.
Do not use a wet cloth or water to clean the card. Do not
clean or touch any component or PCB.
1.4 FCC Notice
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 2 of
the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when
the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions found herein, may cause
harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause
harmful interference in which case the user will be
required to correct the interference at their own expense.
Any changes or modifications to the unit not expressly
approved by Altinex, Inc. could void the user's authority to
operate the equipment.
User's Guide

Advertisement

loading
Need help?

Need help?

Do you have a question about the MT315-101 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Altinex MT315-101

  • Page 1 Step 6. Connect any 2-wire conductor, up to 984 ft (300 m), between the MT315–101 transmitter and a compatible receiver; MT315-102 or TP315-102. Step 7. On a LAN, the enclosure IP can be discovered via a UDP broadcast of “?Altinex” to port 30305. 3. Warranty and Return Policies Please visit the Altinex website at www.altinex.com...
  • Page 2 MT315-101 User’s Guide 4. Technical Specifications Specifications are subject to change due to design improvements. Please see www.altinex.com for up to date information. Features/Description MT315–101 Mechanical MT315–101 Input Connectors Slots HDMI Video HDMI F, Type A (1) Material Aluminum Output Connectors...
  • Page 3 Local monitor output The MT315-101 HDMI over Anywire transmitter allows the transmission of 1080P HDMI signals up to 300 m using a simple 2-conductor cable. A single transmitter drives up to 4 receivers using either 4 individual wire pairs over 300 m each, or by daisy chaining the receivers.
  • Page 4 MT315-101 User’s Guide 6. Application Diagrams Diagram 1: Typical Setup 400-0663-001...
  • Page 5 MT315-101 User’s Guide Diagram 2: Internal View 400-0663-001...
  • Page 6 MT315-101 User’s Guide Diagram 3: Multiple Receiver Setup 400-0663-001...
  • Page 7 MT315-101 User’s Guide 7. Operation 7.1.3 Conventions Used in this Manual Card IDs: 7.1 Control The MT315–101 has many advanced remote-control In this manual, cards are referenced by their card ID which is capabilities when used in the MultiTasker enclosure. These...
  • Page 8 This command is common to all excluding the main microprocessor. Power to video and cards, but there are no features to save on the MT315-101. audio circuitry is turned off. Use for saving power but to Command Format: [CiiS] keep response time short returning to normal operation.
  • Page 9 = On/off (x = 1 to enable, 0 to disable) This command puts the card into firmware update mode. Feedback Prefix Definitions: Only use when working with Altinex Technical Support. MT Card Model Number Command Format: [PRGCii] VR Firmware Revision 11.
  • Page 10 MT315-101 User’s Guide 7.3 Summary of Commands Common Commands Card status [CiS] Save all settings [?C] Parseable card status […S] Save single command [DISP] Return card information [FRST] Factory reset [GROUP] Set or read group number [HWEN] Hardware enable/disable [MOD]...
  • Page 11 If the image is poor the devices may be incompatible. • Run a different cable. The cable in question may be damaged or shorted. System Failure Please call the Altinex Customer Service Department at (714) 990-2300 to have the unit repaired. 400-0663-001...