5.2.4 How to Clear the Error Buffer

The error code buffer is cleared in the following cases:
• By using the CLEAR command in the SAM menu
• By using the CLEAR command in the Factory mode:
• By using the following key sequence on the remote control transmitter: "062599" directly followed by the OK button.
• If the contents of the error buffer have not changed for 50 hours, the error buffer resets automatically.
Note: If you exit SAM by disconnecting the mains from the television set, the error buffer is not reset.

5.3 Panel Code

Press the following key sequence on a standard RC transmitter: "062598" directly followed by MENU and "xxx", where "xxx" is a 3 digit decimal value
of the panel type: see column "Display Code" in below tab. After resetting the Display Code, restart the set immediately.
CTN_ALT BOM
32PHD5813/55
32PHG5813/78
32PHG5813/77
43PFG5813/78
43PFG5813/77
43PFD5813/55
43PFT5813/57
32PHG5833/77
32PHG5813/78
32PHG5813/77
43PFG5813/78_AUO
 
Panel Type
TPT320B5-AT011H S011M
TPT320B5-AT011H S011M
TPT320B5-AT011H S011M
TPT430H3-DUYSHA.G S1CAG
TPT430H3-DUYSHA.G S1CAG
TPT430H3-DUYSHA.G S1CAG
TPT430H3-DUYSHA.G S1CAG
TPT320B5-AT011H SV016J
TPT320B5-AT011H SV016C
TPT320B5-AT011H SV016C
TPT430H3-HVN01.U S082S
 
Display Code
208
208
208
207
207
207
207
208
216
216
217