ELECTRICAL CONNECTIONS (CONT.)
5
4-WIRE POWER CORD INSTALLATION
WARNING: The neutral wire of the supply
circuit must be connected to the neu-
tral terminal located in the center of the
terminal block. The power leads must
be connected to the left and the right
terminals of the terminal block. The 4th
grounding lead must be connected to
the frame of the range with the ground
plate and the ground screw.
A
Remove the 3 lower terminal nuts from the terminal
block. Remove the ground screw and ground
plate and retain them.
B
Cut and discard the ground strap. DO NOT DIS-
CARD ANY SCREWS.
C
Insert the one ground screw into the power cord
ground wire terminal ring, through the ground plate
and into the frame of the range.
D
Insert the 3 terminal screws (removed earlier)
through each power cord terminal ring and into
the lower terminals of the terminal block. Be certain
that the center wire (white/neutral) is connected to
the center lower position of the terminal block.
Tighten screws securely into the terminal block.
E
Skip to Step 8 and proceed with the installation.
Installation Instructions
6
3-WIRE CONDUIT INSTALLATION
A
Loosen the 3 lower terminal screws from the termi-
nal block. Insert the center bare wire (white/ neu-
tral) tip through the bottom center terminal block
opening. On certain models, the wire will need to
be inserted through the ground strap opening and
then into the bottom center block opening. Insert
the two side bare wire tips into the lower left and
the lower right terminal block openings. Tighten the
screws until the wire is firmly secure (approximately
20 inch-lbs.).
NOTE: ALUMINUM WIRING:
Aluminum building wire may be used but it must be
rated for the correct amperage and voltage to
make connection. Connect wires according to this
Step 6 or Step 7 depending on number of wires.
Wire used, location and enclosure of splices, etc.,
must conform to good wiring practices and local
codes.
B
Skip to Step 8 and proceed with the installation.