Gate safety edge transmitter

Advertisement

Assemble Cable Grip. Unscrew the cable grip about 3/4 of the way
STEP 5
and thread the safety edge cable through the cable entry on the transmitter.
TO SAFETY EDGE
DTG Code Setting. To set a code, select any valid combination of
STEP 7
ON and OFF positions for the switch keys numbered 1 - 8. Refer to receiver
installation instructions to code receiver switches.
Wire Receiver. Wire receiver obstacle output to obstacle input on
STEP 9
operator. Refer to operator and receiver wiring instructions.
DRG
Digital Gate Receiver
CHANNEL
ONE
GRAY
YELLOW
CHANNEL
TWO
Replacing Batteries. If LED indicator fails to light when test button
STEP 11
is pushed, replace with a 9 volt alkaline or lithium battery.
UNSNAP
BATTERY CLIP
WARNING!
NO LOW BATTERY
REPORTS ARE SENT
WHEN THE BATTERY
GETS WEAK. USER IS
CAUTIONED TO TEST
THE TRANSMITTER
MONTHLY.
INSTR,INSTL,DTG
Linear P/N: 211906 Rev-D
Material: 20 Lb. Mead Bond
Size 8.500" x 11.000"
Ink: Black
Side 2 of 2
Scale: 1-1
USE A PAPER CLIP
TO SET THE EIGHT
KEYS
GATE OPERATOR
MANUAL ACCESS
REQUEST
1
COMMON
RELAY
2
24 V RADIO POWER
3
OBSTACLE INPUT
1
COMMON
OBSTACLE
2
REMOVE BATTERY
FROM HOLDER
Attach Cable. Attach safety edge cable to terminals as shown.
STEP 6
Tighten cable grip assembly using pliers to assure a water tight seal.
TO SAFETY EDGE
Test Safety Edge. Test safety edge connection by pressing the
STEP 8
safety edge. The test indicator light should come on.
PRESS
WITH
HAND
Test System. Activate the gate to close. As the gate is closing, press
STEP 10
the safety edge with your hand. Gate should stop and reverse.
CAUTION! DO not stand in the path of the closing gate.
WARNING!
NO AUTOMATIC
SUPERVISION OF
A DAMAGED GATE
EDGE SENSOR IS
PROVIDED. USER IS
CAUTIONED TO TEST
THE TRANSMITTER
REGULARLY.
LIMITED WARRANTY
This Nortek Security & Control LLC product is warranted against defects in material and workmanship for twenty-four (24) months. This
warranty extends only to wholesale customers who buy direct from Nortek or through Nortek's normal distribution channels. Nortek
Security & Control LLC does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of
the dealer's warranty, if any. There are no obligations or liabilities on the part of Nortek Security & Control LLC for consequential damages
arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue,
warranties express or implied.
All products returned for warranty service require a Return Authorization Number (RA#). Contact Nortek Security & Control Returns at
1-855-546-3351 for an RA# and other important details.
FCC & IC Notice
This device complies with Part 15 of the FCC Rules and Industry Canada license exempt standard(s). Operation is subject to the
following two conditions:
1)
This device may not cause harmful interference, and
2)
This device must accept any interference received, including interference received that may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes:
1)
(1) l'appareil ne doit pas produire de brouillage, et
2)
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.
WARNING:
equipment.
Copyright © 2019 Nortek Security & Control LLC
ATTACH EDGE SENSOR
CABLE TO TERMINALS
TEST INDICATOR SHOULD
LIGHT WHEN SAFETY EDGE
IS PRESSED
PRESS
SAFETY EDGE
CLOSE GATE