You have chosen a high-quality product. To ensure that you get a lot of enjoyment from this product, here are a few
more tips:
After transport:
Since the unit uses refrigerant, improper transport can sometimes occur despite careful instructions on the carton.
Therefore, we ask you to let it stand upright for at least 4 hours before using it for the first time so that the
refrigerant in the unit can settle again.
In case of any problems:
We hope that the unit meets your expectations! If, despite the greatest possible care, there should ever be cause
for complaint, please contact us briefly, as we are very concerned about your satisfaction and would like to clear up
any misunderstanding.
Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany
www.AKTOBIS.de
Email: Info@Aktobis.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WDH-FGA1075 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aktobis WDH-FGA1075

  • Page 1 We hope that the unit meets your expectations! If, despite the greatest possible care, there should ever be cause for complaint, please contact us briefly, as we are very concerned about your satisfaction and would like to clear up any misunderstanding. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: Info@Aktobis.de...
  • Page 2: Important Safety Instructions

    ! In this case, please contact a specialist and do not try to repair the unit yourself !!! Examples: Fan does not run during operation, fuse has blown or compressor rattles loudly. Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: Info@Aktobis.de...
  • Page 3 13. active carbon filter 14. sealing strip for window gap (3-part) 15. condensation water drain hose 16. remote control 17. adapter for connecting the warm air hose to the air conditioner Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: Info@Aktobis.de...
  • Page 4: Operating Recommendations

    If you have installed the closing strip at the window gap/door gap/wall, now insert the adapter into its intended recess. Alternatively, guide the adapter through the window gap/door gap to the outside so that the warm exhaust air can be blown out unhindered. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: Info@Aktobis.de...
  • Page 5 Insert the activated carbon filter into the rear upper filter frame 2.5. Now put the filter holder on the filter frame 2.6. Finally, push the filter unit back into the air conditioner. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: Info@Aktobis.de...
  • Page 6 The default target temperature is 24°C. At the same time, the operation/signal lights turn on. (Note: The room temperature display panel can display values from 0°C to 50°C. ) Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: Info@Aktobis.de...
  • Page 7 During operation, press the TIMER button to select the desired remaining time of the air conditioner. (A value between 1 - 24 hours can be selected). After this selected operating time has elapsed, the unit automatically switches off completely. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: Info@Aktobis.de...
  • Page 8 Make sure that the outlet of the exhaust air is always given and not obstructed by other objects !  Only appropriately trained specialists are permitted to carry out repairs to the cooling lines and the compressor! Always contact a specialist in case of a problem ! Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: Info@Aktobis.de...
  • Page 9 3. The drain hose can be extended or also replaced. In this case, please use a suitable hose. A 3/4 inch hose is best suited/fitting. Rubber stopper Sealing cap Plastic hose Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: Info@Aktobis.de...
  • Page 10: Troubleshooting

    Make sure that the air intake, the exhaust air and the exhaust air duct for the warm air are not blocked and have sufficient free space.  Check whether the room temperature is perhaps already below the selected target temperature. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: Info@Aktobis.de...
  • Page 11: Technical Data

    The above data have been determined in accordance with EU standard: EN 14511, as well as EU safety and test regulations: EN 60335-2-40. COOLING - dry temperature = 35°C; wet temperature = 24°C Fuse: F2AL250V or T2AL250V Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: Info@Aktobis.de...
  • Page 12 They will then recycle the appliance. I wish you much pleasure with this appliance. Keep these instructions for use in a safe place ! Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: Info@Aktobis.de...