Installation Of Indoor, Outdoor Unit; Select The Best Location - LG MULTI A3UQ26GFA0 Installation Manual

Hide thumbs Also See for MULTI A3UQ26GFA0:
Table of Contents

Advertisement

INSTALLATION OF INDOOR, OUTDOOR UNIT

8
INSTALLATION OF INDOOR, OUTDOOR UNIT
Read completely, then follow step by step.

Select the best location

Indoor unit
1
Do not have any heat or steam near the
unit.
2
Select a place where there are no obsta-
cles in front of the unit.
3
Make sure that condensation drainage can
be conveniently routed away.
4
Do not install near a doorway.
5
Ensure the spaces indicated by arrows from
the wall, ceiling, fence or other obstacles.
6
Use a stud finder to locate studs to pre-
vent unnecessary damage to the wall.
!
CAUTION
Install the indoor unit on the wall where
the height from the floors more than 2,3
meters.
More than
10cm
More than 2,3m
More than
10cm
More than 2,3m
More than
10cm
More than 2,3m
More than 20cm
More than
10cm
More than 20cm
More than
10cm
More than 20cm
More than
10cm
Outdoor unit
1
If an awning is built over the unit to pre-
vent direct sunlight or rain exposure, make
sure that heat radiation from the condens-
er is not restricted.
2
Ensure that the spaces indicated by arrows
around front, back and side of the unit.
3
Do not place animals and plants in the path
of the warm air.
4
Take the air conditioner weight into
account and select a place where noise
and vibration are minimum.
5
Select a place so that the warm air and
noise from the air conditioner do not dis-
turb neighbors.
Rooftop Installations
If the outdoor unit is installed on a roof struc-
ture, be sure to level the unit. Ensure the roof
structure and anchoring method are adequate
for the unit location. Consult local codes
regarding rooftop mounting.
more than 60cm
more than
30cm
more than
70cm
more than 60cm
more than
30cm
more than
70cm
more than
30cm
more than
60cm
more than
30cm
more than
60cm