Filter: Open the filter cover (fig.3.2) and inspect the filter. Replace if excessively dirty.
7.6.
STORAGE:
If the blower will not be used for an extended period, remove the filter and battery and store them in a clean, dry, cool place free of
solvent-based vapours.

8. TROUBLESHOOTING

8.1.
WELDING SHIELD;
PROBLEM
Difficult to see through filter
Filter does not darken when arc is struck
Filter darkens without arc
Filter remains dark after welding
8.2.
FILTER AND HOOD;
FAULT
Blower does not supply air to hood
Battery pack's charge lasts less than
expected
Blower cannot be turned off
Battery red level light is flashing
Danger light is on, alarm sounds or blower
vibrates
Parts support is available for this product. Please email sales@sealey.co.uk or telephone 01284 757500
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
POSSIBLE CAUSES
Cover lens dirty
Filter lens dirty
Grind Mode Selected
Sensors or Solar Panel blocked
Set Sensitivity to LOW
Low voltage of lithium batteries
Set Sensitivity to HIGH
Set Delay to MAX
POSSIBLE SOLUTION
1. Press On switch to start blower
2. Recharge battery
3. Verify battery is properly connected to blower
4. Remove blockage from blower outlet and breathing tube
1. Ensure battery pack is fully charged
2. Replace battery
3. Replace charger
4. Check the air filter and replace it if necessary
Press ON/OFF button for one second
Charge or replace the battery
Check the blower air flow paths are clear.
01284 703534
sales@sealey.co.uk
Original Language Version
SUGGESTED SOLUTIONS
Clean or replace cover lens
Clean filter lens
Adjust to 'Weld' mode.
Make sure sensors or solar panel are
exposed to weld arc without blocking
Adjust Sensitivity to required level
Replace with new lithium batteries if indicator
turns red
Adjust Sensitivity to required level
Adjust Delay to required level