“right to left” or “right hand” unit will start with the scrap area and/or wash tank on the right hand side� At Stoddart, we take pride in manufacturing the Power Soak line and are committed to standing behind our customers and products 100%�...
The manufacturer declines any liability for damages to persons and/or things due to an improper/wrong and/or unreasonable use of the machine Service • Only specifi cally trained/qualifi ed Technicians (Stoddart, one of our service agents, or a similarly qualifi ed persons) should carry out any and all repairs, maintenance and services www.stoddart.com.au Page 4 Due to continuous product research and development, the information contained herein is subject to change without notice.
The unit MUST be on a level surface for the water to drain properly IMPORTANT This unit must be installed in accordance with AS/NZ 3500.1 www.stoddart.com.au Page 5 Due to continuous product research and development, the information contained herein is subject to change without notice.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard� Please contact Stoddart for parts and we will advise how to do this in order to avoid any electrical hazard •...
All electrical connections must be “liquid tight” and readily accessible for inspection after installation without moving the Power Soak machine or any of its accessories. www.stoddart.com.au Page 7 Due to continuous product research and development, the information contained herein is subject to change without notice.
It may be necessary to relocate and/or replace the existing grease trap� Be sure that the grease trap meets or exceeds the local plumbing codes� IMPORTANT It is recommended that all machines be installed using new 1/2” or larger Ball-Valve Shut Off Valves. www.stoddart.com.au Page 8 Due to continuous product research and development, the information contained herein is subject to change without notice.
This box will contain the fasteners and sealant that will be required for assembly of the Power Soak� Locate the box labelled “OPEN FIRST” to find fasteners and sealant used for the installation www.stoddart.com.au Page 9 Due to continuous product research and development, the information contained herein is subject to change without notice.
From the outside of the tank place the rubber vibration ring over the threaded body of the drain followed by the Teflon ring and then the drain nut� Tighten the nut “hand tight” until the handle is installed� www.stoddart.com.au Page 10 Due to continuous product research and development, the information contained herein is subject to change without notice.
Allow the sealant to dry before filling the sink with water (see instructions on the side of the sealant container for drying time)� After the sealant has dried, fill the sink with water and check for leaks around the drain� www.stoddart.com.au Page 11 Due to continuous product research and development, the information contained herein is subject to change without notice.
Be sure that all the legs are seated in the bottom of the sockets� Use an allen wrench (5/32) to tighten the set screws in all of the sockets� After tightening the set screws, apply silicone sealant (supplied with the machine) to the set screw openings in order to seal the openings� www.stoddart.com.au Page 12 Due to continuous product research and development,...
Sealant applied to the underside of JBZ joint and face end of the end plate www.stoddart.com.au Page 13 Due to continuous product research and development, the information contained herein is subject to change without notice.
Page 15
Apply the grey-coloured NSF approved sealant to all the sink joints and wipe the excess away leaving a smooth sanitary joint www.stoddart.com.au Page 14 Due to continuous product research and development, the information contained herein is subject to change without notice.
Wire Harness Zip-Type Wire Ties IMPORTANT The chemical supplier must finalize the setup of the chemical dispensing system. www.stoddart.com.au Page 15 Due to continuous product research and development, the information contained herein is subject to change without notice.
Complete the faucet assembly according to the manufacturer’s instructions which are included with the faucet� Attach water lines to the faucet so that the lines extend below the sink� This will make the plumbing easier to complete when the machine is placed against the wall� www.stoddart.com.au Page 16 Due to continuous product research and development, the information contained herein is subject to change without notice.
NSF approved sealant provided with the Power Soak� Seal around the screw heads to be sure they do not allow water to leak behind the splashback� Wipe off all excess sealant leaving a smooth, clean and sanitary bead of sealant on all the edges� www.stoddart.com.au Page 17 Due to continuous product research and development, the information contained herein is subject to change without notice.
Review the information tag for determining the specific requirements of the machine being installed (see Verify the Electric Requirements section of this instruction booklet)� www.stoddart.com.au Page 18 Due to continuous product research and development,...
Shelving Reinstall any shelving that was removed for convenience of installation� If the shelving is damaged or corroded, it is recommended that the shelving be replaced� www.stoddart.com.au Page 19 Due to continuous product research and development, the information contained herein is subject to change without notice.
The Chemical Dispensing System must be checked by a representative of the manufacturer� It will need to be verified that the proper amount of chemical is being dispensed and that the proper chemical concentration is maintained during operation� www.stoddart.com.au Page 20 Due to continuous product research and development, the information contained herein is subject to change without notice.
Devices (AWG) (Amps) Power Soak Systems Without Heaters Minimum Minimum Overcurrent System Supply Phase Protective Voltage Conductor Devices (AWG) (Amps) www.stoddart.com.au Page 21 Due to continuous product research and development, the information contained herein is subject to change without notice.
~ ~ ~ * * * * * * Contact Stoddart Service Department 24/7 at 1300 307 289. Membrane Error Please have this “Error Code” information available prior to calling the Stoddart Service Department 24/7 at 1300 307 289. Pump Does Not Work / Intermittent Running Look For...
Page 24
Australia Service / Spare Parts Sales Tel: 1300 307 289 Tel: 1300 79 1954 Email: service@stoddart.com.au Email: sales@stoddart.com.au Email: spares@stoddart.com.au www.stoddart.com.au Australian Business Number: 16009690251 New Zealand Service / Spare Parts Sales Tel: 0800 935 714 Tel: 0800 79 1954 Email: service@stoddart.co.nz...
Need help?
Do you have a question about the Power Soak PS-200 and is the answer not in the manual?
Questions and answers