Vent the tank of a sewage station in accordance with local plumbing codes.
Fasteners
• Only use fasteners of the proper size and material.
• Replace all corroded fasteners.
• Make sure that all fasteners are properly tightened and that there are no missing

Torque values

All screws and nuts must be lubricated to achieve correct tightening torque. Screws that
are screwed into stainless steel must have the threads coated with suitable lubricants to
prevent seizing.
If there is a question regarding the tightening torques, please contact the local sales and
service representative.
Screws and nuts
Table 3: Stainless steel, A2 and A4, torque Nm (ft-lbs)
Property
M4
M5
class
50
1.0 (0.74)
2.0 (1.5)
70, 80
2.7 (2)
5.4 (4)
100
4.1 (3)
8.1 (6)
Table 4: Steel, torque Nm (ft-lbs)
Property
M4
M5
class
8.8
2.9 (2.1)
5.7 (4.2)
10.9
4.0 (2.9)
8.1 (6)
12.9
4.9 (3.6)
9.7 (7.2)
Hexagon screws with countersunk heads
For hexagon socket head screws with countersunk head, maximum torque for all property
classes must be 80% of the values for property class 8.8 above.

Check before start-up

Check that the pump installation is completed according to the applicable Installation,
Operation, and Maintenance manual.
• Check the horizontal positioning of the jet aerator according to the dimensional
• Check that the water jet propagates freely without meeting obstacles or side walls.
Flygt jet aerator JA 112, JA 117, JA 217, JA 317 Installation, Operation, and Maintenance Manual
Lifting equipment is required to handle the jet aerator. The lifting chain and the shackle
should be in stainless steel and inspected every year.
The minimum height between the lifting hook and the ground must be sufficient to be
able to lift the jet aerator out of the tank.
fasteners.
M6
M8
3.0 (2.2)
8.0 (5.9)
9.0 (6.6)
22 (16)
14 (10)
34 (25)
M6
M8
9.8 (7.2)
24 (18)
14 (10)
33 (24)
17 (13)
40 (30)
drawings.
The direction of flow that is created must not conflict with flows of other mixers or jet
aerators installed.
M10
M12
M16
15 (11)
27 (20)
65 (48)
44 (32)
76 (56)
187 (138)
66 (49)
115 (84.8) 248 (183)
M10
M12
M16
47 (35)
81(60)
194 (143)
65 (48)
114 (84)
277 (204)
79 (58)
136 (100) 333 (245)
Installation
M20
M24
M30
127 (93.7) 220 (162) 434 (320)
364 (268)
629 (464) 1240 (915)
481 (355)
M20
M24
M30
385 (285)
665 (490) 1310
(966.2)
541 (399)
935 (689) 1840
(1357)
649 (480)
1120
2210
(825.1)
(1630)