Disassembly; Disposal; Technical Specifications - Captron CANEO 41 Series Original Operating Instructions

Display / standard
Table of Contents

Advertisement

NOTICE
Solvents contained in cleaning agents can attack the
plastic of the button!
Clean the surface of the button with a neutral cleaning agent
4
or a damp microfiber cloth.

Disassembly

► Disconnect the system from its voltage supply and secure it
against being switched on again.
► Insert the flat head screwdriver into the groove (D) on the cover
ring (A) and remove the cover ring with the screwdriver via lever
action.
► Loosen the screw connections and disconnect the electrical
connection.

Disposal

Different types of electrical and electronic components must be
recycled according to their type. All applicable statutory, state and
local laws and regulations must be complied with.

Technical specifications

Technical specifications
series4x
Operating voltage
Load current
Reverse polarity protection
Short circuit protection
Voltage drop
Power consumption at 24 V
Operating temperature
Degree of protection IP
Degree of protection IK
Communication interface
DC 12 - 24 V (8.4 to 31.2 V)
max. 200 mA
Protection of all cables/lines
Protected against short circuit and overload
Max. 2.5 V at 200 mA load current
Max. 90 mA
-25°C (-13°F) to 50°C (122°F)
Front IP69K Maximum unevenness in mounting
surface < 0.2 mm
IK08
IO-Link specification V1.1