Captron CANEO 41 Series Original Operating Instructions

Captron CANEO 41 Series Original Operating Instructions

Display / standard

Advertisement

Quick Links

CANEO
CANEO
Original operating instructions
Original operating instructions
series41 Display / Standard
series41 Display / Standard

Advertisement

Table of Contents
loading

Summary of Contents for Captron CANEO 41 Series

  • Page 1 CANEO CANEO Original operating instructions Original operating instructions series41 Display / Standard series41 Display / Standard...
  • Page 2: Table Of Contents

    Table of Contents Foreword..................3 Safety................... 3 General safety................3 Notes and symbols used............3 Personnel qualifications............4 Intended use................5 Reasonably foreseeable misuse..........5 General description..............6 Assembly..................6 Recommended screw types............. 7 Maximum dimensions of the screws........8 Operation..................8 Configuring CANEO series41 with IO-Link.......8 Maintenance.................
  • Page 3: Foreword

    Foreword These operating instructions are intended for technicians/installers and operators and should be kept for future reference. Read these operating instructions carefully and make sure that you have fully understood the contents before installing or working with the SENSORswitches. Metric and imperial measurements are used in drawings. Imperial measurements are marked with [ ].
  • Page 4: Personnel Qualifications

    WARNING Warning designates a hazardous situation, which, if ignored, may lead to death or serious injury. The symbol next to the warning indicates the type and source of the danger. CAUTION Caution designates a hazardous situation, which, if ignored, may lead to injury. The symbol next to the warning indicates the type and source of the danger.
  • Page 5: Intended Use

    standards, who can evaluate the work assigned to them correspondingly and recognize potential risks. WARNING Improper work on electrical systems! Electric shock can result in death or life- threatening injuries. Before working on electrical systems, disconnect them from their voltage supply and secure them against being switched on again.
  • Page 6: General Description

    General description The supplied SENSORswitch can have options that differ from those shown in this manual. This does not affect the function. The SENSORswitch is equipped with different color LEDs to indicate operating conditions. The LEDs are actuated differently depending on the pin configuration.
  • Page 7: Recommended Screw Types

    Requirements: Mounting surface is level and clean (maximum unevenness of the mounting flange 0.1 mm). ► Disconnect the system from its voltage supply and secure it against being switched on again. ► Set the desired position of the SENSORswitch and drill a hole with a diameter of 25 mm .
  • Page 8: Maximum Dimensions Of The Screws

    DIN EN ISO 1481 Ø3.9 mm DIN EN ISO 7049 Ø3.9 mm Maximum dimensions of the screws The drawing shows the maximum dimensions of the screws. Operation series41 is operated by touching the button surface. Configuring CANEO series41 with IO-Link For information on configuring the SENSORswitch, see our website series4x...
  • Page 9: Disassembly

    NOTICE Solvents contained in cleaning agents can attack the plastic of the button! Clean the surface of the button with a neutral cleaning agent or a damp microfiber cloth. Disassembly ► Disconnect the system from its voltage supply and secure it against being switched on again.
  • Page 10: Connection Options

    series4x Measuring principle Capacitive Type of actuation Touch Actuation force No actuation force required max. altitude 3000 m above standard zero Relative air humidity Max. 95%, non-condensing Connection options Plug M12, 3-pin Plug M12, 4-pin Plug M12, 5-pin...
  • Page 11: Connection Plan

    Connection plan 3-pin brown +VDC black IO - Link Communication (NPN / PNP NO / NC) blue The product description will indicate the configuration. 4-pin white brown +VDC black IO - Link Communication (NPN / PNP NO / NC) blue The product description will indicate the configuration.
  • Page 12 5-pin white gray brown +VDC black IO-Link communication (NPN / PNP NO / NC) blue The product description will indicate the configuration.
  • Page 13: Drilling Pattern

    Drilling pattern Metric and imperial measurements are used in drawings. Imperial measurements are marked with [ ].
  • Page 14: Dimensional Drawing

    Dimensional drawing 63,15 2,486 Metric and imperial measurements are used in drawings. Imperial measurements are marked with [ ].
  • Page 15: Technical Specifications

    Technical specifications Manual updates CAPTRON reserves the right to make changes to the contents of this manual as needed. The most current version can be found on our website www.captron.com Imprint The operating instructions have been authored and published by CAPTRON Electronic GmbH Johann-G.-Gutenberg-Straße 7...
  • Page 16: Product Description / Product Description

    Product description / Product description...

Table of Contents