Important reminder:
Make sure that the equipment is placed on a flat, stable surface, able to withstand high tem-
peratures.
Make sure that all switches are in the off position.
Make sure that all terminal connections are secured accordingly.
Important!
Information regarding the buttons and the index of the display panel can be seen in the
paragraph "control panel."
A. First use
1. Connect the device via the electricity cable included in the delivery to the mains power supply.
2. With all functions switched off and all connections properly secured, switch the device on by
activating the main current switch, located on the back of the device.
3. The display shows the product name temporarily in a scrolling way. After finishing the
scrolling, all lines will show "off" (see picture below). The system stays like this until a function
is activated.
B. Switching from Celsius to Fahrenheit
1. Connect the device via the electricity cable included in the delivery to the mains supply.
2. Press and hold the "up" button to put the device into the Celsius mode. The display will show
"Aoyue 866C." The last digit will show the used temperature scale. "C" stands for Celsius and
"F" for Fahrenheit.
3. Press and hold the "down" button on the soldering iron whilst turning the system on to change
it into the Fahrenheit mode. The display will show "Aoyue 866F." The last digit will show the
used temperature scale. "C" stands for Celsius and "F" for Fahrenheit.
C. Heat gun
1. Follow the steps of the "first use."
2. Adjust the air flow of the heat gun to the centre position.
3. Activate the switch of the "heat gun" (9 on the control panel).
4. The system immediately begins to create an air flow of medium speed, the heat of the air flow
will slowly start heating up to 100 
ted by the air temperature display panels 1 of the heat gun/control panel.
5. Adjust the wished air flow.
6. Adjust the desired temperature of the heat gun via the buttons for the temperature adjustment
of the heat gun (4 on the control panel). The prefix of the display will change from "H" into "h"
for the temperature of the hot-air fan and shows that the air temperature has been adjusted. It
will change back to "H" (the actual temperature) whilst the temperature is starting to increase
again or decreases until the desired temperature is reached.
Important:
When you adjust the air temperature, we strictly recommend to decrease the air
flow level, to be able to regulate the system temperature. This protects the heating element on
the inside from excessive heat and additionally avoids the possibility of neighbouring parts be-
ing affected by a temperature shock.
7. The rework can be started 1 min after reaching the desired hot air temperature and the air flow
level, as shown on display 1.
8. When the work has been finished, place the heat gun onto the rack and do not switch the
electricity supply off immediately.
9. First of all, deactivate the activation button of the heat gun to begin the automatic cooling pro -
cess. The system begins to blow out air (room temperature) fast, to reduce the warmth from
the heat gun and bring the temperature to a responsible and safe level of 90 
the abbreviation on the display of the heat gun will change from "H" to "C" whilst the temperat -
© by WilTec Wildanger Technik GmbH
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
(pre-set system parameters). These values are represen
Item 90866
-