MyRunN/manual 04.10.28 10:48 AM ページ2 i-MyRun.N Instruction Manual Electrophoresis System COSMO BIO CO., LTD. Toyo-Ekimae Bldg., 2-20, Toyo 2-Chome, Koto-ku, Tokyo 135-0016, Japan Tel: +81-3-5632-9605 Fax: +81-3-5632-9614...
Page 2
This product complies with the requirements terms and conditions of sale of the company of Low Voltage within the Cosmo Bio Co., Ltd., group that Directive (LVD) 73/23/EEC through the supplies them. A copy of these terms and harmonized standard EN 61010-1, 1993 + A1, conditions is available on request.
Page 3
Any electrophoresis equipment connected to the power supply should meet the requirements of the IEC 1010-1:1993 electrical standard. 7. _Note that the output is connected to the chassis/reference earth. 8. _Please contact Cosmo Bio if a problem occurs. (Never replace the fuse yourself.) Never open the cover.
Page 4
MyRunN/manual 04.10.28 10:48 AM ページ5 2.2 Built-in safety features The IMR-201 has been tested and complies with the IEC 61010-1 (EN 61010-1) electrical safety standard. 1. _Functional earth leakage. Should the power supply be connected to an electrophoresis unit that has a leakage path to earth, the IMR-201 will detect this fault and the high voltage will be turned off.
Page 5
MyRunN/manual 04.10.28 10:48 AM ページ14 4. Operation 1. Set up for the system The power supply and electrophoresis tank have some of safety interlock systems. If you work with the system, make sure of the following points. 1. _Put a buffer in this electrophoresis tank. (Suitable buffer concentration) 2.
Page 6
MyRunN/manual 04.10.28 10:48 AM ページ7 3. _Set the comb. Select a comb with the desired number of teeth. Insert the comb into the hole to which the B Insert the comb into the hole to which the A mark to the left of the gel casting tray is mark to the right of the gel casting tray is attached if you need the same four-lane attached if you need the same six-lane distance.
Page 7
MyRunN/manual 04.10.28 10:48 AM ページ12 2. _Plug the power cord into the power outlet. Note: The i-MyRun.N system has the mini gel support guide. The guide can support two large gels or four small gels (one large gel and two small gels) on this glide.
Page 8
Wipe the instrument regularly with a damp cloth. Let the instrument dry completely before use. Otherwise, no user maintenance is necessary. All servicing should be entrusted to qualified personnel only. Please contact Cosmo Bio Co., Ltd., for more service information. 6. Environmental Condition 1. _Indoor use.