Installation
5.2
Reversing the door
➤ Reverse the door as shown (fig. 7, page 5 to fig. 0, page 5).
I
NOTE
The LED of the automatic door control (optional) must always be located
opposite the door hinge.
For versions with automatic door control, proceed as follows:
1. Pull out the LED (fig. 1 3, page 3).
2. Lay the cable in the guide.
3. Insert the LED on the device's foot on the other side.
5.3
Fixing the cooling device
Ventilation (fig. a, page 6)
• Ventilation must be provided as shown in alternatives A, B, C or D.
• Ventilation grills (1), if used, must have openings of at least 200 cm² each.
• The minimum clearance between the cooling device's back and the surrounding
structure should be as follows:
No. in
fig. a, page 6
2
3
• The ventilation duct must at least measure 105 mm x the width of the cooling
device.
• The entire cooling unit must project into the ventilation duct as shown.
• Air passing through the ventilation duct must not be preheated by any source of
heat.
• The ventilation duct must be kept free from any obstacles. Especially portable
multi socket outlets or portable power supplies, which can get warm, must not
be kept at the rear of the cooling device.
➤ Fix the cooling device through its fixing feet as shown (fig. b, page 7).
16
Min. distance
20 mm
105 mm
RH418NTE, RH418NTEG