Genvex Vanvex Optima 180 User Manual

Genvex Vanvex Optima 180 User Manual

Domestic hot water
Hide thumbs Also See for Vanvex Optima 180:

Advertisement

Quick Links

GB
User Manual
Vanvex Optima 180
Domestic Hot Water
Version 3.07 - 0310

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vanvex Optima 180 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Genvex Vanvex Optima 180

  • Page 1 User Manual Vanvex Optima 180 Domestic Hot Water Version 3.07 - 0310...
  • Page 2: Table Of Contents

    Optima 180 Table of contents Page 1. Users Guide 1.1 Use ..................3 Altering of the operation data..........3 1.3 Operating menu ..............1.4 Factory default scheme ............5 1.5 Defrost programme.............. 5 2. Function 2.1 Description Optima180 ............6 2.2 Extra capacity ..............
  • Page 3: Users Guide

    Optima 180 1. Users guide P3: The operating thermostat is pressed The required domestic water temperature may be set between 0 - 55 °C, which is heated by the Optima 180 AC comes with a factory setup, which heat pump. enables an immediate start of the unit.
  • Page 4: Operating Menu

    Optima 180 display will now show the first point E0 in the operating help heating the water when the intake air temperature menu. The operating menu will close and return to the is below the temperature set in E10. The function is main menu if a button has not been pressed for 15 sec.
  • Page 5: Factory Default Scheme

    Optima 180 fan will run faster, using more energy, if the values are set E20: Solar col hyst to low. If a solar collector has been connected, a temperature Factory setting: 5 difference may be set, this must be between the water 1.4 Factory default scheme temperature in the solar collector and the operating thermostat of the hot water tank, before the circulation...
  • Page 6: Function

    When the high pressure switch interrupts, the has been tapped. The compressor will run until the entire red Genvex logo will flash until the red reset button on tank has been heated to the set temperature again. the pressure switch is activated. In order to prevent a...
  • Page 7: Maintaining

    Damage caused sure the water connections are checked after a few days by a blocked safety valve is not covered by the Genvex to make sure there are no leaks. Also check that the warranty.
  • Page 8: Fault Finding

    Optima 180 4. Fault finding 4.3 The heat pump will not run! Please test if: The heat pump is equipped with the following safety devices: ● power is connected? ● power is turned on at the wall plug? 4.1 High pressure switch: ●...
  • Page 9: Electric Diagramme

    Optima 180 Notes:...
  • Page 10: Flow Diagramme

    Optima 180 Notes:...
  • Page 11 Optima 180 Notes:...
  • Page 12 Tel.: + 385/ (0) 1/ 65 45 407 Fax: + 385/ (0) 1/ 65 45 409 E-Mail: pichler@zg.hnet.hr Portugal Iberterm PT-4475-493 Nogueira Maia Tel: +351 229 065 123/4 Fax: +351 229 065 125 E-Mail: paulo.neto@iberterm.com Web: www.iberterm.com Published by Genvex A/S, Sverigesvej 6, DK-6100 Haderslev www.genvex.dk...