If the lamp providing the flame effect fails, it can be replaced
as follows:
Disconnect from the mains supply and remove the cover
from the back panel labelled "please change the bulb here".
Remove the failed lamp, and replace by a new 40 W lamp
with a small Edison screw (E14) base.
Replace the cover.
FAULT-FINDING
The EH1432 has a tilt switch which disconnects the power if
the heater falls over. If the heater is not operating, restore it
to an upright position.
The EH1432 has an overheat protection switch, which
disconnects the power if the element gets too hot. The usual
reason for this is because the air-flow has been obstructed,
or the grilles have been blocked. If the heater ceases to
operate, leave it for 20 minutes to cool down, then check that
the grilles are not being obstructed.
Select "Flame effect only" on the switches, and reconnect to
the mains supply. If the flame effect operates, then it is safe
to select the "low heat" or "high heat" settings. If the flame
effect does not operate, or overheat protection switch
operates again, contact an authorised service agent for
repair.