Download Print this page

Honeywell GW-1000-WE Mounting Instructions page 5

Hide thumbs Also See for GW-1000-WE:

Advertisement

• Keep the antenna away from devices that cause wireless
interference such as other Wi-Fi network and
telecommunications equipment.
• Make sure that the antenna is installed perpendicular to
the surface for a good Wi-Fi signal.
• Do not install the antenna close to the floor.
• The Local antenna can be used when the Gateway is
installed in a plastic cabinet/enclosure.
Installing Ferrite Ring
Ferrite ring is supplied with the kit. It must be installed on
the antenna wire somewhere between 10 to 30 cm from the
Gateway.
1. Lift the two locking tabs to open the ferrite ring.
2. Wind the wire three times as shown in the below fig-
ure.
Ferrite Ring
3. Lock the Ferrite ring.
Surface
Antenna Wire
5
GW-1000-WE / GW-1000-NWE GATEWAY
Removing the Extended Terminal
Covers
1. Insert a flat blade screwdriver into the rectangular
slot as shown in the below figure.
Extended Terminal
Cover
2. Use the flat blade screwdriver as a leaver, pull out the
top Extended Terminal Cover.
3. Repeat the steps above to remove the bottom
Extended Terminal Cover.
Removing the Gateway from the
DIN Rail
1. Remove the Terminal Covers if applicable.
2. Disconnect all the communication and power supply
terminals from the Gateway.
3. Uninstall the antenna by turning the antenna termi-
nal nut anticlockwise.
4. Hold the Gateway with one hand and insert a flat
blade screwdriver into the red clip slot.
Flat Blade Screwdriver
5. Pull the red clip downward by using the flat blade
screwdriver.
6. After the Gateway is released from the DIN rail,
slightly tilt the Gateway on the horizontal axis, lift and
detach the Gateway from the DIN rail.
Flat Blade Screwdriver
Insertion slot
+
31-00425 | Rev.10-20
Part Number: 32348979-001

Advertisement

loading

This manual is also suitable for:

Gw-1000-nwGw-1000-nwe