Page 2
NOTES Model Number: Serial Number: Date of Purchase: Retain this manual as a permanent record of your purchase.
Page 3
INTRODUCTION Congratulations on your purchase of a Powr-Flite a 1200 P.S.I. Multi-Surface Cleaner, PF1200RT. You are now equipped to handle any and all commercial carpet cleaning jobs. Shipping and Damage This equipment is thoroughly inspected, tested, and packaged to provide equipment in good operating condition.
IMPORTANT SAFETY PRECAUTIONS IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE USING THIS UNIT Read and understand this owner’s manual and all labels on the unit before operating. Safety is a combination of common sense,staying alert, and knowing how your unit works. Use this unit only as described in this manual.
GENERAL DIAGRAM Hard Surface Tool Recovery Tank Vacuum Inlet Wand Holder Clip Solution Line Pressure Gauge Pressure Adjustment Wand Holder Solution and Vacuum Hose...
Page 6
GENERAL DIAGRAM Manual Dump Hose Loading Wheels Solution Line Inlet Cord Hook Autodump Outlet Vacuum Switch Dual Circuit Indicator Pump Switch Autodump Circuit Breaker Autodump Switch Transport Wheels...
GENERAL INSTRUCTIONS MACHINE SET UP This machine is designed as a direct feed solution system with a recovery tank with the option to auto dump. To set up your machine: GENERAL INSTRUCTIONS 1. Make sure hoses are in good condition and spray nozzle on wand is tight. 2.
GENERAL INSTRUCTIONS OPTIONAL: CLEANING CARPET WITH A CARPET WAND (Not Included) 1. Verify the vacuum hose and solution hose are securely connected to the machine and carpet wand. 2. Set the PSI to no more than 800 psi to clean carpet. CAUTION: Damage to carpet may occur if the PSI is set too high.
Page 9
4. Inspect vacuum hoses for holes and loose cuffs. 5. Clean machine housing with an all purpose cleaner and damp cloth. 6. Inspect the machine for leaks and loose hardware. 7. Lubricate wheels and casters with oil or grease . 8.
TROUBLESHOOTING PROBLEM CAUSE SOLUTION Inlet basket filter is clogged. Clean filter. Loose drain hose connection. Tighten drain hose. Loose recovery tank lid. Position the lid correctly. Poor pick up. Damaged hose. Replace hose. Suction relief is open on Adjust or close suction relief wand.
OPTIONAL ACCESSORIES NOT INCLUDED Viper Renew Viper Venom 7” Spinner Hand for restorative Wet/Dry Vac for routine Tool #HP7 cleaning #VR4 Tool #WD30A cleaning #VV4 Wonder Wand™ Pressure 1000 p.s.i. 3 Jet Washer #WW1000 Gun #X1470 Wet/Dry Vac Wand #WD29 (2 required)
Page 12
For warranty information go to www.Powr-Flite.com A Tacony Company 3101 Wichita Court • Ft. Worth, TX 76140-1755 1-800-880-2913 • Fax: 1-817-551-0719 • www.Powr-Flite.com PF1200RT-MAN 05/2021...