30" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
The technical data tables for the nozzles and burn-
ers are shown below:
1 - Circular Dual Flame burners. 2 - Circular Single
Flame burners. 3 - Fish burner.
Burner power and bypass table
Burner
1
No.
Max.
18000
Power
(BTU)
Min.
750
Power
(BTU)
Bypass
75 + 26
(mm)
Natural gas nozzles table (Pressure in W.C.P.: 5")
Burner
1
No.
Ext.
180
nozzle
number
Int. noz-
75
zle
number
LPG nozzles table (Pressure in W.C.P.: 10")
Burner
1
No.
Ext.
115
nozzle
number
Int. noz-
48
zle
number
2
3
5500 +
12000
5500
2400 +
3500
2400
58
45 + 45
2
3
155
108 + 108
2
3
102
67 + 67
Location of the appliance's Gas and
Electric connections
4 Gas connection
5 Electrical connection
Connect the gas supply line to the unit pressure reg-
ulator using a 1/2" flex gas line connector between
the manual shut-off valve and the pressure regula-
tor. A metal flex line or fixed metal pipe must be
used to connect the gas to the appliance. If a metal
gas line cannot be used, consult your local certified
electrician or local electric codes for proper ground-
ing.
Check the supply line connections for leaks using a
soap solution or non-corrosive leak detection fluid.
Do not use a flame of any sort.
WARNING
Install a gas shutoff valve near the
appliance. After installation, it must be easily
accessible in an emergency.
1. Turn on gas.
2. Apply a soap solution or non-corrosive leak
detection fluid to all joints and fittings in the gas
connection between the shut-off valve and the
cooktop. Include gas fittings and joints in the
cooktop if connections may have been disturbed
during installation. Bubbles appearing around fit-
tings and connections indicate a leak.
3. If you detect a leak, turn off supply line gas shut-
off valve and tighten connections.
4. Retest for leaks by turning the gas supply line
shutoff valve on. When the leak check has been
completed (no bubbles appear), the test is com-
plete.
5. Wipe off all residues of the soap solution or
detection fluid.