Electrical & Wiring; Specifications - Waterco DIGIHEAT 2.4kW Installation And Operation Manual

Titanium in line spa heaters
Hide thumbs Also See for DIGIHEAT 2.4kW:
Table of Contents

Advertisement

ELECTRICAL & WIRING
• The electrical wiring must be permanently hardwired by qualified electrician in
accordance with all the local wiring rules.
• A properly rated isolating switch must be connected from the supply to the digiHeat
with a minimum rated power circuit as specified on the table below.
• To access and carry out the electrical connections, the front cover with the digital
controller needs to be removed. The front cover of the digiHeat is hinged from the
bottom to make it easier to remove and replace.
To remove the front cover :
i) remove the 6 spring loaded quarter turn locking pins first
ii) pull the cover gently from the top
iii) now slide the cover across to the left to disconnect the hinges.
This equipment must be installed and serviced by a qualified technician.
WARNING
!
Improper installation may result in property damage, serious injury or death.
Improper installation and/or operation will void the warranty.
DigiHeat Titanium Single Phase

SPECIFICATIONS

Model
Weight
(kg)
2.4 kW
3.5
3.6 kW
3.5
4.8 kW
3.5
6.0 kW
3.5
10.8 kW
9.4
14.4 kW
9.4
18.0 kW
9.5
24.0 kW
9.5
Supply
Frequency
Voltage
(Hz)
(volts)
240
50
240
50
240
50
240
50
415
50
415
50
415
50
415
50
digiheat Titanium In line Spa Heaters I 03
DigiHeat Titanium Three Phase
Amps
Minimum
Circuit
Size
(Amps)
10
15
15
20
20
25
25
30
15 /phase
20
20 /phase
25
25 /phase
30
35 /phase
40
IP
Max
Rating
Pressure
(kPa) @
31m head
IP23
300
IP23
300
IP23
300
IP23
300
IP23
300
IP23
300
IP23
300
IP23
300

Advertisement

Table of Contents
loading

Table of Contents