Operating Digiheat Titanium - Waterco DIGIHEAT 2.4kW Installation And Operation Manual

Titanium in line spa heaters
Hide thumbs Also See for DIGIHEAT 2.4kW:
Table of Contents

Advertisement

08 I digiheat Titanium In line Spa Heaters
OPERATING THE DIGIHEAT
After familiarising yourself with the layout and settings of the touch pad, fill the spa with
water and follow the instructions below.
We suggest you instruct all the people who will use the spa or pool fitted with the digiHeat
on how to operate it by either by giving them this manual or by showing them yourself.
reading, understanding and following this guide should lead to trouble free operation of
the digiHeat spa heater.
1. Fill the spa with water and then switch on the water pump.
2. Switch on the power to the digiHeat. The controller will then display "OFF" or the water
temperature. If the pump is not running or if there is insufficient water flow, "nFl" will be
displayed.
(Please refer to troubleshooting section of this manual for "nFl")
3. If the display reads "OFF" press the on/off button to switch on the digiheat, the
temperature will then be displayed.
4. Press and release the up or down button and the set temperature will be displayed with
either the ˚C or ˚F indicator led flashing.
• To increase the desired set temperature press and hold the up button which will
allow the set temperature to be raised up to a maximum of 40˚C (104˚F). release the
button when the desired temperature is displayed on the screen.
• To decrease the desired water temperature press and hold the down button. release
the button when the desired temperature is displayed on the screen.
5. With an accurate thermometer, check the actual water temperature in the spa is the
same as the temperature displayed on the digiheat.
If the displayed water temperature is different to the actual water temperature, the
controller will need to be calibrated. This can only be done whilst the temperature is
shown in ˚C. refer to the section "temperature calibration".
6. When switching the digiheat off during a heating cycle, allow the heater to cool down
by keeping the water pump operating for two minutes.