Performance Data For Toftejorg Sanimidget Retractor; Performance Data For Toftejorg Sanimidget Retractor Pneumatic Driven - Yumpu TE91A750-EN1 Instruction Manual

Table of Contents

Advertisement

Technical Data
(continued)

Performance Data for Toftejorg SaniMidget Retractor

Flow rate
Note: The inlet pressure has been taken immediately before the machine inlet. In order to achieve the
performance indicated in the curves, the pressure drop in the supply lines between pump and machine
must be taken in consider

Performance Data for Toftejorg SaniMidget Retractor Pneumatic driven

Air supply pressure
Air quality
Instruction Manual, Toftejorg SaniMidget Retractor
IM-TE91A750-EN1
ation.
:
2-5 bar (29-75 psi)
:
Clean filtered max. 40 µm
Dry, dew point max. 5°C
Non-lubricated possible