Download Print this page

Motion Sensor Light Control; Manual Mode; Installation; Requirements - Acclaim Lighting LFL2M Installation And Wiring Instructions

Advertisement

Motion Sensor Light Control

Model: LFL2WHM/LFL2ABZM
Questions or problems? Before
to your retailer, refer to
returning
the
troubleshooting
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during
daylight hours.
This package includes:
Cover
Plate
Light Control
Mounting Bolt
Mounting St rap

Requirements

•The light control requires 120-volts AC.
If you want to use Manual Mode,the control must
be wired through a switch.
• Som e codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in
wet
locations.
Operation
Mode:
On-Time
Test
10 Seconds
1 or 5 Min
Auto
To Dawn*
Manual
* resets to Auto Mode at dawn.
Note: When first turned on wait about 40
seconds for the circuitry to calibrate.
Set the switch
on the bottom of the
sensor to TEST.
Set switch to
1 or 5 minutes.
guide in this manual
2 Wire
Connectors
Sensor
Gas ket
Ru bber
Plug
2 Scr ews
Works: Day
Night
x
x
x
x
TEST
1 5 MIN
TEST
AUTO
TEST 1 5 MIN
Manual mode only works at
night because daylight re -
turns the sensor to AUTO.
Flip the light switch off
for one second then back
on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with
the ON-TIME switch in the 1,
or 5 position.
TEST
AUTO

MANUAL MODE

If you get confused while s witching
modes, turn the power off f or one minute , then
bac k on. After the cali bration time the control
will be in the AUTO mode.
For easy installation, select an existing light
with a wall switch for replacement.
For best performance,mount the fixture about
8 ft(2 .4m) above the ground.NOTE:If fixture
is mounted higher than 8 ft.(2.4m),aiming the
sensor down will reduce coverage distance.
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
wing the sensor head towards the clamp screw
1.
S
joint.
2. Then rotate the sensor head clockwise 180°
so the controls face down.
If the sensor pops out of the ball joint,loosen
the clamp screw and push the sensor back into
the ball joint.Tighten the clamp screw when done.
2
MANUAL MODE
1 Second
OFF then...
... back on.
Mode Switc
h Summary
Move switch to
1 or 5 minutes
Flip light switch
off f or one second
then ba ck on

Installation

Wall Mount
Eave Mount
Clamp Screw
Controls
Controls

Advertisement

loading