Vibration Monitoring Unit Type He100; Intended Use; Scope Of Supply; Documents And Certificates - Hauber HE100 Series Operating Instructions Manual

Vibration monitoring unit
Table of Contents

Advertisement

HAUBER-Elektronik GmbH
4

Vibration monitoring unit type HE100

The HE100-type vibration monitoring unit is used to measure and monitor absolute bearing vi-
brations in machines in line with DIN ISO 10816.
It has the following features:
Operating principle: The two-wire system.
Measurement value: The effective value (rms) of the vibration velocity in mm/s, in accord-
ance with DIN ISO 2954.
Analogue current output: Interference-free DC signal from 4–20 mA, proportional to the
measuring range of the monitoring unit.
Cable breaks on the monitoring cable can be detected by a downstream evaluation com-
ponent: DC signal value < 3.5 mA.
5

Intended use

The HE100-type is used exclusively for measuring mechanical vibrations in machines and me-
chanical systems. Its use is only permissible within the specifications stated in the data sheet.
Main fields of application: Fans, ventilators, blowers, electric motors, pumps, centrifuges, sep-
arators, generators, turbines and similar oscillating mechanical systems.
6

Scope of supply

All versions include:
Vibration monitoring unit
Instruction Manual
7

Documents and Certificates

You can find the following documents and certificates for HE100 type at
ektronik.de
EU type examination certificate ATEX, no.: PTZ 16 ATEX 0029 X Rev 3
IECEx certificate of conformity, no.: PTZ 18.0009 X Rev 2
UL certificate of conformity, no.: E507077-20191126
EACEx certificate RU C-DE.HA65.B.00053/19
EAC Declaration
8

Transfer of liability when operating in potentially explosive atmospheres

The owner of the system is exclusively liable for the appropriate configuration of the electrical
connections with respect to explosion protection regulations and correct commissioning.
If the system is installed by a sub-contractor on behalf of the owner, the system may only be
commissioned after the sub-contractor has issued written confirmation in the form of a certificate
of installation that the system has been installed correctly and professionally in accordance with
the applicable legal regulations.
The operator is obliged to notify the responsible authorities of the initial commissioning of explo-
sion-protected systems or system components and their re-commissioning following extensive
changes or maintenance.