Warmco HR10 Instruction Manual page 15

Premix unit air heater
Table of Contents

Advertisement

Installation Roof terminal
1. Check the components on possible damages.
2. Taking the roofing into account, determine the type of weather collar synthetic file or universal
pitched roof flashing; for a flat roof an aluminium flat roof flashing.
3. Determine where the flue terminal will be positioned.
4. Make a hole for the flue terminal from the outside. Ensure that no saw dust or dust gets into the
appliance.
5. Fit the weather collar..
6. Carefully insert the flue terminal through from the outside. Attention: do not tum the cap.
7.
Put the flue terminal into a vertical position using an air level. (If desired, cover plates, to be
supplied separately,can be fitted)
8. Fix the supplied wall clamp round the flue terminal and fit
it to the roof construction. Do not tighten the clamp yet.
9. Fit the gasket and the twin-tube connection. Make sure
that the gasket is not damaged. Ensure that the flue tube
and the air inlet tube are not exchanged; the flue tube is
the pipe in the centre of the flue terminal.
10.
Finally, secure the roof wall clamp and check that all
steps have been carried out correctly.
Installing Wall terminal
1. Check the components on possible damages.
2. Determine where the flue terminal will be positioned.
3. Make a hole for the flue terminal. Ensure that no saw dust or dust gets into the appliance.
4. Carefully insert the flue terminal the outside. Attention: do not tum the cap.
5. Fix the terminal horizontally using an air level
6. Mark the holes and drill the holes in the outside wall for the fixation of the terminal.
7. Fix the terminal with screws. Eventually seal the fixation with kit.
8. Fix the shield on inner wall.
9. Fit the gasket and the twin-tube connection. Make sure that the gasket is not damaged. Ensure
that the flue tube and the air inlet tube are not exchanged; the flue tube is the pipe in the centre of
the flue terminal.
10. .Check that all steps have been carried out correctly.
Instructions condensing Air heaters type HR version HR-GB-4001-a