FLINTAB 47-11 User Manual
Hide thumbs Also See for 47-11:

Advertisement

Quick Links

\\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc
Flintab AB
Kabelvägen 4
553 02 JÖNKÖPING
Weightindicator 47-11
User Manual
Tel 036-31 42 00
mail@flintab.se
USER MANUAL
2019-02-11 / Tony Kübek
www.flintab.se
4-56020
Edition 1.0
Page 1 (27)

Advertisement

Table of Contents
loading

Summary of Contents for FLINTAB 47-11

  • Page 1 USER MANUAL 4-56020 2019-02-11 / Tony Kübek Edition 1.0 Weightindicator 47-11 User Manual Page 1 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se 553 02 JÖNKÖPING...
  • Page 2 553 02 JÖNKÖPING +46 36-31 42 00 For latest contact and address information see: mail@flintab.se https://www.flintab.se/kontakt/saelj-och-servicekontor/ https://www.flintab.se/ Page 2 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se 553 02 JÖNKÖPING...
  • Page 3: Table Of Contents

    7.2.1 Status, wait for power on zero ................24 Specifications ....................25 8.1 Dimensions .......................... 25 8.2 Operating conditions ......................26 Manufacturers declaration of conformity ............27 Page 3 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se...
  • Page 4 2019-02-11 / Tony Kübek Edition 1.0 Revisions Date Revision Notes Signed 2018-11-22 First draft 2018-02-11 First edition Page 4 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se 553 02 JÖNKÖPING...
  • Page 5: Introduction

    Flintab scales and indicators combine weighing functions and features to provide exceptional flexibility, user friendly operation and reliability. This manual covers the normal every day usage of the 47-11 weight indicator, for detailed instructions, interfacing and installation, consult the 4-55424 Weight indicator 47-11 Instruction manual.
  • Page 6: Installation

    Installation in this case only require the connection of peripheral equipment as per schematics below: Power Scale Ethernet Peripheral Serial :1 Display Serial:2 Page 6 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se 553 02 JÖNKÖPING...
  • Page 7: Internal Graphic Lcd With Panel Touch Buttons

    2019-02-11 / Tony Kübek Edition 1.0 Internal graphic LCD with panel touch buttons The 47-11 indicator can be fitted with an optional internal graphics LCD with integrated touch-button panel. Depending on configuration, the display can use different basic layouts for displaying weight and related information. Relevant weighing functions will be shown on the display next to a touch-button.
  • Page 8: Standard Layout

    Sensor error = SEN /TMP Interval/Range = 1,2 or 3 Symbol indicates instrument running on battery power Page 8 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se 553 02 JÖNKÖPING...
  • Page 9: Integrated Capacity Name-Plate

    See examples below: • Single interval: • Triple interval • Triple range Page 9 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se 553 02 JÖNKÖPING...
  • Page 10: Start-Up Sequence

    <Abort>/<Back> button Page 10 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se...
  • Page 11: Weighing Functions

    See below examples: • Scale with no load does not show exact zero (e.g. residue material from last weighing). Page 11 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se...
  • Page 12 Note: When the weight value is within ± 0.25 scale intervals of true zero, the sign ’o’ appears on the display before the zero weight value, this is also called ‘absolute zero’. Page 12 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se...
  • Page 13: Semi-Automatic Tare

    ”NET” indication. Touch-button • Press the <Tare> key again to return to gross weight display. Page 13 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se...
  • Page 14: Manual Tare Entry (Pt)

    • By pressing, and holding, the <Tare> button for >3seconds or pressing the dedicated manual tare button <PTare> the display will shift to manual tare entry. Touch-button Touch-button Page 14 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se...
  • Page 15 • To remove the effect of the tare and return to gross weight display, briefly press the <Tare> key again. Page 15 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se...
  • Page 16: Printing (Single)

    ”PRINT” appears on the display. Transmission is according to settings for the PRINT-protocol. Touch-button • After printing the display reverts to show normal weight. Page 16 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se...
  • Page 17: Printing (Totalizing)

    • Display shows current weight and is stable • By pressing the <ADD> touch-button, current weight will be added to the accumulating sum Touch-button Page 17 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se...
  • Page 18 • By pressing the <SUM> touch-button, current accumulated sum will be printed then, after printout, the sum will be automatically cleared Touch-button Page 18 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se...
  • Page 19: Parts Counting

    • Place several items/parts on the scale, the greater the number the more accurate the calculation of the item-weight will be. Minimum recommended number of items are 10. Page 19 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se...
  • Page 20 • The indicator will now enter count mode, where the display will show number of items instead of the weight value. Number of items/parts Current weight Item/part weight Page 20 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se...
  • Page 21 Touch-button Touch-button Page 21 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se...
  • Page 22: Connections

    See section 2 Installation for location of the connectors. For a more detailed description, pin-out and connection diagram for the interfaces consult the 4-55424 Weight indicator 47-11 Instruction manual Load cell / scale connection The load cell/scale connector is a standard shielded RJ45 plug, located furthest from the DC-plug.
  • Page 23: Status/Error Indications

    . . . Three dots Corrective actions: • Remove load from scale platform • Check wiring/connection to the scale Page 23 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se...
  • Page 24: Status Indications

    Optional action: • The operator can abort the power-on zero setting by pressing <Back> (cancel), the indicator will then enter operational mode. Page 24 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se...
  • Page 25: Specifications

    USER MANUAL 4-56020 2019-02-11 / Tony Kübek Edition 1.0 Specifications Dimensions With internal display: (11) Panel cut-out Page 25 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se 553 02 JÖNKÖPING...
  • Page 26: Operating Conditions

    <5W Operating temperature range -10C°- +40C° (legal for trade) Relative humidity Max. 85%, non-condensing Electromagnetic class Page 26 (27) \\FS01\Avd\85\Produkter\VIKTINDIKATOR\Handhavande\47-11\4-56020 rev 1-0 Weightindicator 47-11 User manual 20190211.doc Flintab AB Tel 036-31 42 00 Kabelvägen 4 mail@flintab.se www.flintab.se 553 02 JÖNKÖPING...
  • Page 27: Manufacturers Declaration Of Conformity

    47-11-xxx Type designation Vi, Flintab AB, försäkrar på eget ansvar att den produkt som denna försäkran avser överensstämmer med de krav som anges i ovan angivna EG-direktiv. We, Flintab AB, declare under sole responsibility that the product to which this...

Table of Contents