10. Keypad operation
Entry
Function
User code
Arming / Disarming (Setting\Unsetting)
Arming without a code
F1 /
Partial arming
F2 /
Door lock opening
F3 /
F4
Memory reading
F5
New master code (example: F5 1234 2789 2789)
F6
User codes setting (example: F6 1234 03 3344)
Disarming under duress
F7 /
F8
Appliance control (F81 = ON, F80 = OFF)
F0 M.code User test mode (example F0 1234)
N
Escape & fault detail reading
Motion detector
JA-60P
Doors, Windows
JA-60N
JK-16 PROFI
Power (230 V AC)
11. Specifications
Power
Power supply
Backup battery
Backup power output
13VDC, the max. permanent current is 0.4
Consumption of the control panel is
Hard-wired inputs
Wireless zones
16 zones (2 detectors can be enrolled to each
Wireless controllers
Access codes
Wired outputs
Programmable outputs PgX , PgY connect to the GND max. 0,1 A
Siren output
Working frequency* 433.92 MHz; digital hopping code; supervised
communication
Comply with
Security grade
Environmental class
Safety
EMC
Radio characteristics
Can be operated according to
Jablotron Alarms a.s. hereby declares that the JA-83K "OASiS"
control panel is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC. The original of
the conformity assessment can be found on the web site
www.jablotron.com, Technical Support section.
Note: Dispose of batteries safely depending on the type of the
batteries and local regulation. Although this product does not
contain any harmful materials we suggest you to return the
product to the dealer or directly to the producer after usage.
Control panel
JA-63KR
Wireless keypad
JA-63F
3/4
230 VAC, max 0.1 A, supervised, class II
A type (EN 50131-6)
12 V, 2.26 Ah, normal life time 5 years
or 1A for max. 15 min (1 cycle per hour),
30 mA; JA-60E 25 mA
4 input zones, selectable triggering:
max. 8 (JA-60F, RC-22, RC-44)
master code and 14 user codes.
Alarm relay dry contacts 1A/60V;
EN 50131-1, EN 50131-6
2 (low to medium risk)
II indoor – general (-10 to 40oC)
ETSI EN 300220
ERC REC 70-03
Indoor siren
UC-260
(230 V AC)
Remote control
RC-4x
12 V, 0.7 A
EN 60950-1
ETS 300683